Yokogawa AGP813 High-Speed Protection Module
Popular Product

Yokogawa AGP813 High-Speed Protection Module


Manufacturer :Yokogawa

Product Number:AGP813

Type:High-Speed Protection Module

Condition:New and Original

Lead Time:In stock

Certificate:COO/Test Report

Dimension:144 x 100 x 30 mm

Weight:0.28 kg

Price:USD147

Product Description

The AGP813 is designed for high-speed protection and control applications in industrial automation. Below are the key specifications and features:

Voltage Inputs

  • Number of Input Channels:
    • 4 channels (high-speed cycle; isolated)
    • 6 channels (basic cycle; isolated)
  • Input Signal: 1 to 5 V
  • Accuracy: ±4 mV
  • Drift Due to Ambient Temperature: ±4 mV / 10°C
  • Input Impedance:
    • Powered: 1 MΩ
    • Not powered: 100 kΩ
  • Allowable Input Voltage: 30 V DC
  • Filtering: Collectively applied across all channels

Pulse Inputs

  • Number of Input Channels: 4 channels (basic cycle; isolated)
  • Input Impedance: 10 kΩ (at AEGP1D)

Magnetic Pickup (MPU) Inputs

  • Input Signal: 0.5 to 150 Vpp
  • Input Frequency: 50 Hz to 25 kHz
  • Accuracy:
    • ±1 Hz (50 Hz to 2 kHz)
    • ±0.05% of reading (2 kHz to 25 kHz)
  • Input Sensitivity:
    • Without Hysteresis:
      • 50 to 500 Hz: 0.5 Vpp or more
      • 500 Hz to 5 kHz: 1.0 Vpp or more
      • 5 to 25 kHz: 2.0 Vpp or more
    • With Hysteresis:
      • 50 to 500 Hz: 1.0 Vpp or more
      • 500 Hz to 5 kHz: 2.0 Vpp or more
      • 5 to 25 kHz: 4.0 Vpp or more

Active Pickup Inputs

  • Input Signal Thresholds:
    • TYPE1:
      • VH: 2.0 to 24 V
      • VL: 0 to 0.8 V
      • Duty: 50% ±5%
    • TYPE2:
      • VH: 2.4 to 24 V
      • VL: 0 to 1.2 V
      • Duty: 50% ±5%
  • Input Frequency: 0.04 Hz to 2 kHz
  • Accuracy: ±0.1% of reading

Digital Inputs (SOE)

  • Number of Input Channels:
    • 4 channels (high-speed cycle; isolated)
    • 8 channels (basic cycle; isolated)
  • Rated Input Voltage: 24 V DC (Sink)
  • Input ON Voltage: 18 to 26.4 V DC
  • Input OFF Voltage: 5 V DC or less
  • Input Current: 4.1 mA ±20%
  • Maximum Allowable Input Voltage: 30 V DC

Digital Outputs

  • Number of Output Channels:
    • 4 channels (high-speed cycle; isolated)
    • 8 channels (basic cycle; isolated)
  • Output Type: Current sinking
  • Maximum Load: 100 mA per channel; 30 V DC
  • Maximum Voltage for ON: 0.3 V DC
  • Maximum Current Leak for OFF: 0.1 mA
  • On/Off Delay: 1 ms (Typical)
  • Scan Cycle:
    • 5 ms (high-speed cycle)
    • 10 ms (basic cycle)

Withstanding Voltage

  • Between system and field: 500 V AC for 1 minute
  • Between different types of inputs/outputs: 500 V AC for 1 minute

External Connection

  • Dedicated Cable: AKB337-M005, M007, M010

General Specifications

  • Maximum Power Consumption: 900 mA (5 V DC)
  • Weight: Approx. 0.28 kg
Popular Product

Yokogawa AGP813 High-Speed Protection Module

Manufacturer :Yokogawa

Product Number:AGP813

Type:High-Speed Protection Module

Condition:New and Original

Lead Time:In stock

Certificate:COO/Test Report

Dimension:144 x 100 x 30 mm

Weight:0.28 kg

Price:USD147

Product Description

The AGP813 is designed for high-speed protection and control applications in industrial automation. Below are the key specifications and features:

Voltage Inputs

  • Number of Input Channels:
    • 4 channels (high-speed cycle; isolated)
    • 6 channels (basic cycle; isolated)
  • Input Signal: 1 to 5 V
  • Accuracy: ±4 mV
  • Drift Due to Ambient Temperature: ±4 mV / 10°C
  • Input Impedance:
    • Powered: 1 MΩ
    • Not powered: 100 kΩ
  • Allowable Input Voltage: 30 V DC
  • Filtering: Collectively applied across all channels

Pulse Inputs

  • Number of Input Channels: 4 channels (basic cycle; isolated)
  • Input Impedance: 10 kΩ (at AEGP1D)

Magnetic Pickup (MPU) Inputs

  • Input Signal: 0.5 to 150 Vpp
  • Input Frequency: 50 Hz to 25 kHz
  • Accuracy:
    • ±1 Hz (50 Hz to 2 kHz)
    • ±0.05% of reading (2 kHz to 25 kHz)
  • Input Sensitivity:
    • Without Hysteresis:
      • 50 to 500 Hz: 0.5 Vpp or more
      • 500 Hz to 5 kHz: 1.0 Vpp or more
      • 5 to 25 kHz: 2.0 Vpp or more
    • With Hysteresis:
      • 50 to 500 Hz: 1.0 Vpp or more
      • 500 Hz to 5 kHz: 2.0 Vpp or more
      • 5 to 25 kHz: 4.0 Vpp or more

Active Pickup Inputs

  • Input Signal Thresholds:
    • TYPE1:
      • VH: 2.0 to 24 V
      • VL: 0 to 0.8 V
      • Duty: 50% ±5%
    • TYPE2:
      • VH: 2.4 to 24 V
      • VL: 0 to 1.2 V
      • Duty: 50% ±5%
  • Input Frequency: 0.04 Hz to 2 kHz
  • Accuracy: ±0.1% of reading

Digital Inputs (SOE)

  • Number of Input Channels:
    • 4 channels (high-speed cycle; isolated)
    • 8 channels (basic cycle; isolated)
  • Rated Input Voltage: 24 V DC (Sink)
  • Input ON Voltage: 18 to 26.4 V DC
  • Input OFF Voltage: 5 V DC or less
  • Input Current: 4.1 mA ±20%
  • Maximum Allowable Input Voltage: 30 V DC

Digital Outputs

  • Number of Output Channels:
    • 4 channels (high-speed cycle; isolated)
    • 8 channels (basic cycle; isolated)
  • Output Type: Current sinking
  • Maximum Load: 100 mA per channel; 30 V DC
  • Maximum Voltage for ON: 0.3 V DC
  • Maximum Current Leak for OFF: 0.1 mA
  • On/Off Delay: 1 ms (Typical)
  • Scan Cycle:
    • 5 ms (high-speed cycle)
    • 10 ms (basic cycle)

Withstanding Voltage

  • Between system and field: 500 V AC for 1 minute
  • Between different types of inputs/outputs: 500 V AC for 1 minute

External Connection

  • Dedicated Cable: AKB337-M005, M007, M010

General Specifications

  • Maximum Power Consumption: 900 mA (5 V DC)
  • Weight: Approx. 0.28 kg