Yokogawa ASD143-P00 Digital Input Module with Built-In Barrier
Yokogawa ASD143-P00 Digital Input Module with Built-In Barrier
Yokogawa ASD143-P00 Digital Input Module with Built-In Barrier
Popular Product

Yokogawa ASD143-P00 Digital Input Module with Built-In Barrier


Manufacturer: Yokogawa

Product No.: ASD143

Part Number: ASD143-P00

Barrier type:Isolated interface

Condition:Brand NEW & in Stock

Product Type: Digital Input Module

Product Origin: Japan

Payment:T/T, Western Union

Weight: Approx. 0.30 kg

Warranty: 12 months

Contact Sales

Product Description

Yokogawa ASD143 Digital Input Module with Built-In Barrier (16-channel, NAMUR Compatible, Isolated) (with ISA Standard G3 option and temperature (-20 to 70 °C) option)

Specification

Item Specification
Model ASD143
Number of input channels 16, isolated
Input signal NAMUR (IEC 60947-5-6) compatible
Withstanding voltage 1500 V AC
Functions Status input (input response time: 15 ms), pushbutton input (minimum ON detection time: 20 ms, maximum ON/OFF cycle: 25 Hz)
Maximum current consumption 150 mA (5 V DC), 110 mA (24 V DC)
Weight Approx. 0.30 kg
External connection Pressure clamp terminal (ATSB4?)
Barrier type Isolated interface

Table List of Parameters (FM) of Modules with Built-in Barrier

Modules Uo (V) Io (mA) Po (mW) Ui (V) Co (nF) Lo (mH) *Remarks (1) IIC IIB IIA
Single 9.8 21 52 1100 7600 11600 26 107 214
Redundant 9.8 41 101 1100 7600 11600 7 28 56

ATEX parameters

  • Uo: Maximum open circuit voltage
  • Io: Maximum output current
  • Po: Maximum output power
  • Ui: Maximum input voltage
  • Co: Output capacitance
  • Lo: Output inductance
  • Remarks (*1): See the Yokogawa ASD143 Digital Input Module with Built-In Barrier manual for more information.

IIC, IIB, and IIA

  • IIC: Equipment intended for use in zones 1 and 2, where an explosive atmosphere consisting of a mixture with air of gases, vapors, or mists is likely to occur occasionally.
  • IIB: Equipment intended for use in zones 1 and 2, where an explosive atmosphere consisting of a mixture with air of dust clouds is likely to occur occasionally.
  • IIA: Equipment intended for use in zones 1 and 2, where an explosive atmosphere consisting of a mixture with air of flammable gases or vapors is likely to occur occasionally.

Please note that these are just general guidelines. The specific ATEX requirements for your application should be determined by a qualified engineer.

Popular Product

Yokogawa ASD143-P00 Digital Input Module with Built-In Barrier

Manufacturer: Yokogawa

Product No.: ASD143

Part Number: ASD143-P00

Barrier type:Isolated interface

Condition:Brand NEW & in Stock

Product Type: Digital Input Module

Product Origin: Japan

Payment:T/T, Western Union

Weight: Approx. 0.30 kg

Warranty: 12 months

Contact Sales

Product Description

Yokogawa ASD143 Digital Input Module with Built-In Barrier (16-channel, NAMUR Compatible, Isolated) (with ISA Standard G3 option and temperature (-20 to 70 °C) option)

Specification

Item Specification
Model ASD143
Number of input channels 16, isolated
Input signal NAMUR (IEC 60947-5-6) compatible
Withstanding voltage 1500 V AC
Functions Status input (input response time: 15 ms), pushbutton input (minimum ON detection time: 20 ms, maximum ON/OFF cycle: 25 Hz)
Maximum current consumption 150 mA (5 V DC), 110 mA (24 V DC)
Weight Approx. 0.30 kg
External connection Pressure clamp terminal (ATSB4?)
Barrier type Isolated interface

Table List of Parameters (FM) of Modules with Built-in Barrier

Modules Uo (V) Io (mA) Po (mW) Ui (V) Co (nF) Lo (mH) *Remarks (1) IIC IIB IIA
Single 9.8 21 52 1100 7600 11600 26 107 214
Redundant 9.8 41 101 1100 7600 11600 7 28 56

ATEX parameters

  • Uo: Maximum open circuit voltage
  • Io: Maximum output current
  • Po: Maximum output power
  • Ui: Maximum input voltage
  • Co: Output capacitance
  • Lo: Output inductance
  • Remarks (*1): See the Yokogawa ASD143 Digital Input Module with Built-In Barrier manual for more information.

IIC, IIB, and IIA

  • IIC: Equipment intended for use in zones 1 and 2, where an explosive atmosphere consisting of a mixture with air of gases, vapors, or mists is likely to occur occasionally.
  • IIB: Equipment intended for use in zones 1 and 2, where an explosive atmosphere consisting of a mixture with air of dust clouds is likely to occur occasionally.
  • IIA: Equipment intended for use in zones 1 and 2, where an explosive atmosphere consisting of a mixture with air of flammable gases or vapors is likely to occur occasionally.

Please note that these are just general guidelines. The specific ATEX requirements for your application should be determined by a qualified engineer.