Our Products
Comprehensive industrial automation solutions for global industries
Contact us
If you are interested in our products and want to know more details,please Contact us,we will reply you as soon as we can.
Honeywell FC-BSN-1608 Safe Namur Sensor Converter
Manufacturer:Honeywell
Product Number:FC-BSN-1608
Product Type:Safe Namur Sensor Converter
Origin:USA
Dimensions:128 x 50 x 145 mm
Weight:0.65 kg
Views:54
Payment Methods:T/T, PayPal, Western Union
Condition:New & In Stock
Warranty:1 Year
Lead Time:1-3 Working Days
Certificate:COO
Courier partners:DHL, UPS, TNT, FedEx and EMS.
Business hours:7*24
Product Description
The Honeywell FC-BSN-1608 Safe NAMUR Sensor Converter is an advanced interface module specifically designed for converting NAMUR-type sensor signals into logic-level signals suitable for direct processing by safety systems such as Honeywell Fail Safe Controller (FSC) and Experion PKS architectures.
NAMUR sensors are widely used in critical applications that demand intrinsically safe field wiring and high-integrity signal isolation. The FC-BSN-1608 module is engineered to accept standard NAMUR signals and convert them reliably for safe operation in Safety Integrity Level (SIL) rated systems. This makes it an ideal component for safety-critical industries where functional safety compliance is required, including oil & gas, chemical processing, power generation, and pharmaceuticals.
The module ensures precise signal conditioning, provides fault detection (such as open/short circuits), and is fully certified for use in hazardous zones. It also includes channel-level diagnostics and galvanic isolation, safeguarding both field and control equipment from electrical disturbances.
The FC-BSN-1608 represents an essential part of modern process safety infrastructure, providing dependable, repeatable NAMUR signal interfacing across a range of industrial sectors.
Product Specifications
| Parameter | Specification |
|---|---|
| Product Name | Honeywell FC-BSN-1608 Safe NAMUR Sensor Converter |
| Part Number | FC-BSN-1608 |
| System Compatibility | Honeywell FSC (Fail Safe Controller), Experion PKS |
| Input Type | NAMUR proximity sensors, contact sensors |
| Number of Channels | 16 isolated input channels |
| Input Signal Type | NAMUR EN 60947-5-6 compliant |
| Input Voltage Range | 8 VDC nominal |
| Input Current Levels | Sensor ON: ≤ 1.2 mA; Sensor OFF: ≥ 2.1 mA |
| Fault Detection | Short-circuit, open-circuit, line fault |
| Galvanic Isolation | Input-to-system logic and channel-to-channel |
| Diagnostics | Channel-level and module-level diagnostics |
| Indication LEDs | Per-channel input status, fault detection |
| Power Supply | 24 VDC nominal (redundant supported) |
| Power Consumption | < 6 W typical |
| Operating Temperature Range | -20°C to +60°C (-4°F to +140°F) |
| Storage Temperature Range | -40°C to +85°C (-40°F to +185°F) |
| Humidity Range | 5% to 95% RH (non-condensing) |
| Shock / Vibration Compliance | IEC 60068 compliant |
| Dimensions (H x W x D) | 128 x 50 x 145 mm |
| Weight | 0.65 kg |
| Mounting Method | DIN rail or panel mount |
| Flame Rating | UL 94V-0 |
| Certifications | CE, UL, CSA, ATEX Zone 2, IECEx |
Applications
Signal conversion for NAMUR proximity and contact sensors
Emergency shutdown systems (ESD)
-
SIL-rated functional safety applications in oil & gas
Overpressure protection systems in chemical plants
-
Process shutdown and interlock functions in power generation
-
Intrinsically safe field device interfacing
Turbine and compressor monitoring systems
Rotating equipment protection
-
Sensor interfacing for pulp & paper machinery safety
-
Safety integration in pharmaceutical and life sciences plants
Product Advantages
High-integrity NAMUR conversion: Converts NAMUR sensor signals for safe processing
Multi-channel density: Supports 16 channels in a compact module
Comprehensive fault detection: Identifies short-circuits, open-circuits, and line faults
Channel isolation: Full galvanic isolation protects both system logic and field devices
Redundant power support: Increases safety system uptime
LED diagnostics: Simplifies commissioning and maintenance with clear status indicators
Certified for hazardous areas: ATEX Zone 2 and IECEx certifications
Designed for SIL-rated applications: Suitable for use in high-integrity process safety loops
Rugged industrial design: Withstands environmental extremes common in heavy industries
Flexible mounting: DIN rail or panel mounting supports new build or retrofit projects
Frequently Asked Questions (FAQ)
What is the main purpose of the FC-BSN-1608?
It converts NAMUR sensor signals into digital signals usable by Honeywell FSC and Experion PKS systems.
How many channels does this module provide?
It provides 16 isolated input channels.
What type of sensors can it connect to?
It connects to NAMUR-compliant proximity sensors or contact sensors.
Is it compatible with safety systems?
Yes — it is designed for SIL-rated safety applications and integrates with Honeywell FSC systems.
What kinds of faults can the module detect?
It detects short-circuits, open-circuits, and line faults.
Is galvanic isolation provided?
Yes — between input channels and from channels to system logic.
Is it certified for hazardous areas?
Yes — ATEX Zone 2 and IECEx certified.
What is the supported input current range?
Sensor ON: ≤ 1.2 mA; Sensor OFF: ≥ 2.1 mA.
Does the module support redundant power?
Yes — it works with redundant 24 VDC power supplies.
How is status indicated?
LEDs indicate channel status and fault conditions at both channel and module levels.
Honeywell FC-BSN-1608 Safe Namur Sensor Converter
Manufacturer:Honeywell
Product Number:FC-BSN-1608
Product Type:Safe Namur Sensor Converter
Origin:USA
Dimensions:128 x 50 x 145 mm
Weight:0.65 kg
Views:54
Payment Methods:T/T, PayPal, Western Union
Condition:New & In Stock
Warranty:1 Year
Lead Time:1-3 Working Days
Certificate:COO
Courier partners:DHL, UPS, TNT, FedEx and EMS.
Business hours:7*24
Product Description
The Honeywell FC-BSN-1608 Safe NAMUR Sensor Converter is an advanced interface module specifically designed for converting NAMUR-type sensor signals into logic-level signals suitable for direct processing by safety systems such as Honeywell Fail Safe Controller (FSC) and Experion PKS architectures.
NAMUR sensors are widely used in critical applications that demand intrinsically safe field wiring and high-integrity signal isolation. The FC-BSN-1608 module is engineered to accept standard NAMUR signals and convert them reliably for safe operation in Safety Integrity Level (SIL) rated systems. This makes it an ideal component for safety-critical industries where functional safety compliance is required, including oil & gas, chemical processing, power generation, and pharmaceuticals.
The module ensures precise signal conditioning, provides fault detection (such as open/short circuits), and is fully certified for use in hazardous zones. It also includes channel-level diagnostics and galvanic isolation, safeguarding both field and control equipment from electrical disturbances.
The FC-BSN-1608 represents an essential part of modern process safety infrastructure, providing dependable, repeatable NAMUR signal interfacing across a range of industrial sectors.
Product Specifications
| Parameter | Specification |
|---|---|
| Product Name | Honeywell FC-BSN-1608 Safe NAMUR Sensor Converter |
| Part Number | FC-BSN-1608 |
| System Compatibility | Honeywell FSC (Fail Safe Controller), Experion PKS |
| Input Type | NAMUR proximity sensors, contact sensors |
| Number of Channels | 16 isolated input channels |
| Input Signal Type | NAMUR EN 60947-5-6 compliant |
| Input Voltage Range | 8 VDC nominal |
| Input Current Levels | Sensor ON: ≤ 1.2 mA; Sensor OFF: ≥ 2.1 mA |
| Fault Detection | Short-circuit, open-circuit, line fault |
| Galvanic Isolation | Input-to-system logic and channel-to-channel |
| Diagnostics | Channel-level and module-level diagnostics |
| Indication LEDs | Per-channel input status, fault detection |
| Power Supply | 24 VDC nominal (redundant supported) |
| Power Consumption | < 6 W typical |
| Operating Temperature Range | -20°C to +60°C (-4°F to +140°F) |
| Storage Temperature Range | -40°C to +85°C (-40°F to +185°F) |
| Humidity Range | 5% to 95% RH (non-condensing) |
| Shock / Vibration Compliance | IEC 60068 compliant |
| Dimensions (H x W x D) | 128 x 50 x 145 mm |
| Weight | 0.65 kg |
| Mounting Method | DIN rail or panel mount |
| Flame Rating | UL 94V-0 |
| Certifications | CE, UL, CSA, ATEX Zone 2, IECEx |
Applications
Signal conversion for NAMUR proximity and contact sensors
Emergency shutdown systems (ESD)
-
SIL-rated functional safety applications in oil & gas
Overpressure protection systems in chemical plants
-
Process shutdown and interlock functions in power generation
-
Intrinsically safe field device interfacing
Turbine and compressor monitoring systems
Rotating equipment protection
-
Sensor interfacing for pulp & paper machinery safety
-
Safety integration in pharmaceutical and life sciences plants
Product Advantages
High-integrity NAMUR conversion: Converts NAMUR sensor signals for safe processing
Multi-channel density: Supports 16 channels in a compact module
Comprehensive fault detection: Identifies short-circuits, open-circuits, and line faults
Channel isolation: Full galvanic isolation protects both system logic and field devices
Redundant power support: Increases safety system uptime
LED diagnostics: Simplifies commissioning and maintenance with clear status indicators
Certified for hazardous areas: ATEX Zone 2 and IECEx certifications
Designed for SIL-rated applications: Suitable for use in high-integrity process safety loops
Rugged industrial design: Withstands environmental extremes common in heavy industries
Flexible mounting: DIN rail or panel mounting supports new build or retrofit projects
Frequently Asked Questions (FAQ)
What is the main purpose of the FC-BSN-1608?
It converts NAMUR sensor signals into digital signals usable by Honeywell FSC and Experion PKS systems.
How many channels does this module provide?
It provides 16 isolated input channels.
What type of sensors can it connect to?
It connects to NAMUR-compliant proximity sensors or contact sensors.
Is it compatible with safety systems?
Yes — it is designed for SIL-rated safety applications and integrates with Honeywell FSC systems.
What kinds of faults can the module detect?
It detects short-circuits, open-circuits, and line faults.
Is galvanic isolation provided?
Yes — between input channels and from channels to system logic.
Is it certified for hazardous areas?
Yes — ATEX Zone 2 and IECEx certified.
What is the supported input current range?
Sensor ON: ≤ 1.2 mA; Sensor OFF: ≥ 2.1 mA.
Does the module support redundant power?
Yes — it works with redundant 24 VDC power supplies.
How is status indicated?
LEDs indicate channel status and fault conditions at both channel and module levels.
Need a Custom Automation Solution?
Our team of experts can design and implement a tailored automation system to meet your specific requirements.

Loading comments...






