Our Products

Comprehensive industrial automation solutions for global industries

Home / ABB / ABB FAU810C10-12010
Product Categories
Product Categories

Contact us

If you are interested in our products and want to know more details,please Contact us,we will reply you as soon as we can.

ABB FAU810 C10-12010 Flame Analysis Unit
ABB FAU810 C10-12010 Flame Analysis Unit
Popular Product

ABB FAU810 C10-12010 Flame Analysis Unit


Item Number:FAU810 C10-12010

Brand: ABB

Lead Time: In stock

Description:Flame Analysis Unit

Payment: T/T

Contact Sales

Product Description

ABB FAU810 (C10-12010) is a flame analysis unit and a standard module in ABB's flame detection system,the unit can be used with both older DFS scanners and newer single-sensor and multi-sensor Uvisor™ SF810 and other ABB flame sensing devices.

Function & Features

  • ABB FAU810 supports all ABB flame detection devices from traditional DFS scanners to the latest Uvisor™ SF810 (single/multi-sensor).
  • ABB FAU810 contains two independent channels, each channel can receive and process flame detector signals, detectors can be combined, and each detector can be independently configured through FAU810 buttons and display, Flame Explorer engineering tool or Profibus.
  • Signal quality calculation: The ABB FAU810 (C10-12010) not only detects the presence or absence of a flame, but also calculates signal quality.

Specifications

Parameter Details
Product Model FAU810
Part Number C10-12010

Flame Failure Relay Drop-Out

Configurable 0.2 to 4 seconds

Flame Relay(s)

Three total, each with Form C contacts

Analog Flame Signal Outputs

Two channels of signals. Each channel may independently monitor Intensity, Frequency, Quality, or AC Amplitude

Self Checking Time Cycle

Electronics shall be checked every 0.1 seconds

Dimension

13cm*12cm*11cm(10.63 in*3.54 in*7.48 in)

FAQ

Q: What is the main function of ABB FAU810 (C10-12010)?

A:  Calculates the intensity and quality of the flame signal;

Determines whether the burner has a flame;

Detects faults in the system itself and the detector;

Sends a signal to the main control system when an unsafe condition is detected.

Q: How can the ABB FAU810 be connected to the factory's control system?

A: Through Profibus DP-V1 and Modbus.

Q: What are the applications of the ABB FAU810?

A: Utility boilers and industrial boilers that require flame detection, etc.

Q: What is the return and exchange policy?

A: Returns or exchanges are accepted within 7 days of receiving the goods if there are any quality issues, excluding damage caused by human error or misuse.

Q:What are the available shipping methods?

A: FedEx, DHL, UPS, and others.

Popular Product

ABB FAU810 C10-12010 Flame Analysis Unit

Item Number:FAU810 C10-12010

Brand: ABB

Lead Time: In stock

Description:Flame Analysis Unit

Payment: T/T

Contact Sales

Product Description

ABB FAU810 (C10-12010) is a flame analysis unit and a standard module in ABB's flame detection system,the unit can be used with both older DFS scanners and newer single-sensor and multi-sensor Uvisor™ SF810 and other ABB flame sensing devices.

Function & Features

  • ABB FAU810 supports all ABB flame detection devices from traditional DFS scanners to the latest Uvisor™ SF810 (single/multi-sensor).
  • ABB FAU810 contains two independent channels, each channel can receive and process flame detector signals, detectors can be combined, and each detector can be independently configured through FAU810 buttons and display, Flame Explorer engineering tool or Profibus.
  • Signal quality calculation: The ABB FAU810 (C10-12010) not only detects the presence or absence of a flame, but also calculates signal quality.

Specifications

Parameter Details
Product Model FAU810
Part Number C10-12010

Flame Failure Relay Drop-Out

Configurable 0.2 to 4 seconds

Flame Relay(s)

Three total, each with Form C contacts

Analog Flame Signal Outputs

Two channels of signals. Each channel may independently monitor Intensity, Frequency, Quality, or AC Amplitude

Self Checking Time Cycle

Electronics shall be checked every 0.1 seconds

Dimension

13cm*12cm*11cm(10.63 in*3.54 in*7.48 in)

FAQ

Q: What is the main function of ABB FAU810 (C10-12010)?

A:  Calculates the intensity and quality of the flame signal;

Determines whether the burner has a flame;

Detects faults in the system itself and the detector;

Sends a signal to the main control system when an unsafe condition is detected.

Q: How can the ABB FAU810 be connected to the factory's control system?

A: Through Profibus DP-V1 and Modbus.

Q: What are the applications of the ABB FAU810?

A: Utility boilers and industrial boilers that require flame detection, etc.

Q: What is the return and exchange policy?

A: Returns or exchanges are accepted within 7 days of receiving the goods if there are any quality issues, excluding damage caused by human error or misuse.

Q:What are the available shipping methods?

A: FedEx, DHL, UPS, and others.

Related Products

Need a Custom Automation Solution?

Our team of experts can design and implement a tailored automation system to meet your specific requirements.