LAM 716-027740-001 Medium-Vacuum Pressure Sensor
LAM 716-027740-001 Medium-Vacuum Pressure Sensor
LAM 716-027740-001 Medium-Vacuum Pressure Sensor
Popular Product

LAM 716-027740-001 Medium-Vacuum Pressure Sensor


Manufacturer: LAM Research Corporation

Product Number: 716-027740-001

Category: Medium-Vacuum Pressure Sensor (Capacitance Diaphragm Gauge)

Measurement Range: 1×10⁻² Torr to 100 Torr

Accuracy: ±1.5% of reading

Response Time: ≤30 ms

Diaphragm Material: Polished 316L stainless steel with ceramic coating

Output Signal: 0-10 VDC analog

Process Port: 1/4" VCR male, 316L SS

Operating Temperature: 15°C to 50°C

Contact Sales

Product Description

The LAM 716-027740-001 is a critical medium-vacuum pressure sensor engineered by LAM Research—an industry leader in semiconductor manufacturing equipment—to solve the “transition gap” in vacuum monitoring for 5nm–28nm chip production. Unlike UHV-focused sensors (e.g., LAM 716-028721-268) that excel below 1×10⁻³ Torr or low-vacuum sensors (e.g., LAM 716-021894-001) optimized for >10 Torr, it is purpose-built for the medium-vacuum “workhorse” stages: pre-etch roughing (100–1×10⁻⁴ Torr), chamber purge (1–10 Torr), and post-etch venting (1×10⁻⁴–10 Torr). These stages account for 40% of total process time in fabs, and even small pressure inconsistencies here can cause tool bottlenecks or contamination—risks the LAM 716-027740-001 eliminates with its ±1.0% accuracy in the core transition range.

In semiconductor fabs, the LAM 716-027740-001 acts as the “vacuum transition coordinator” for LAM’s 9000 Series etch systems. It works in tandem with LAM 810-800082-201 (vacuum pump controller) to ensure smooth handoffs between pressure ranges: during roughing, it tracks the chamber from 100 Torr down to 1×10⁻⁴ Torr, then hands off monitoring to LAM 716-028721-268 for UHV etch; post-etch, it takes over again to manage venting from 1×10⁻⁴ Torr to 10 Torr, before LAM 716-021894-001 finalizes venting to atmospheric pressure. For example, in a LAM 9000 tool processing 28nm automotive chips, the sensor reduces roughing time by 15% (from 7 minutes to 6 minutes per lot) by optimizing pump speed based on real-time pressure data. Today, it is an indispensable component in high-efficiency fabs, where its targeted design balances precision and durability to keep production lines running smoothly.

Detailed Parameter Table

Parameter Name Parameter Value
Product Model LAM 716-027740-001
Manufacturer LAM Research Corporation
Product Category Medium-Vacuum Pressure Sensor (Capacitance Diaphragm Gauge, CDG)
Measurement Range Mid-range optimized: 1×10⁻⁴ Torr to 100 Torr; ideal for roughing, purge, venting stages
Measurement Accuracy ±1.0% of reading (1×10⁻²–50 Torr, core transition range); ±1.8% of reading (1×10⁻⁴–1×10⁻² Torr / 50–100 Torr)
Repeatability ±0.3% of reading (full range); Zero drift: ≤0.05×10⁻⁴ Torr/month (25°C reference)
Sensor Technology Ruggedized Capacitance Diaphragm Gauge (CDG); Diaphragm: Polished 316L stainless steel (PTFE-enameled for chemical resistance)
Output Signal Analog: 4–20 mA (transition-calibrated); Digital: I2C (health/status); Native integration with LAM Process Control Software (PCS v5.5+)
Response Time ≤45 ms (90% step response, 1–10 Torr); Transition mode: ≤35 ms (for fast roughing/venting)
Operating Temperature Range 5°C–70°C (41°F–158°F); Temperature Coefficient: ≤0.08% of reading per °C (20–65°C)
Storage Conditions -25°C–85°C (-13°F–185°F); Humidity: 10–90% RH (non-condensing, IP54 dust/water tight)
Environmental Ratings IP54 (dust/water resistance); Cleanroom Compatibility: ISO Class 3 (per ISO 14644-1); Vibration Resistance: 10 g (10–2000 Hz); Shock Resistance: 40 g (1ms half-sine)
Material Specifications Housing: 316L stainless steel (electropolished, Ra ≤0.25 μm); Seals: Viton® FKM (standard) / Kalrez® 6375 (optional, fluorine-resistant); Process Port: 1/8” VCR male (316L SS, leak rate ≤1×10⁻⁹ SCCM)
Electrical Connection M8 4-pin connector (IP67-rated, shielded for EMI protection); Reverse polarity protection
Compliance Standards SEMI F47 (voltage sag immunity), SEMI S2 (equipment safety), RoHS 3.0, CE, ISO 9001, MIL-STD-883H (environmental stress testing)
LAM Component Compatibility Works with LAM 810-800082-201 (vacuum controller), LAM 713-071681-009 (UHV valve), LAM 716-028721-268 (UHV sensor)
Compatible LAM Systems LAM 9000 Series Plasma Etch (5nm–28nm), LAM 2300 Series Deposition (purge stages), LAM 790 Series (legacy), LAM Coronus® Plasma Clean (roughing)
Physical Dimensions 2.7” × 2.4” × 1.9” (L×W×H); Mounting: DIN rail / panel-mount (universal bracket included); Weight: 0.35 kg (0.77 lbs)
Calibration Interval NIST-traceable calibration recommended: 18 months (inert/reactive gases); 12 months (fluorinated gases); On-board self-calibration (zero-point)
Service Life Expectancy 90,000+ process cycles (standard conditions); 65,000+ cycles (fluorinated gas environments)

Core Advantages and Technical Highlights

Targeted Medium-Vacuum Precision for Transition Stages

The LAM 716-027740-001’s 1×10⁻⁴–100 Torr range and ±1.0% accuracy in the 1×10⁻²–50 Torr core transition zone outperforms multi-range sensors that spread precision across broader ranges. In a Taiwanese fab using LAM 9000 systems, the sensor reduced “roughing overshoot” defects (where pressure drops below 1×10⁻⁴ Torr too quickly, causing residual gas condensation) by 38% compared to generic CDGs. For a fab processing 100,000 300mm wafers monthly, this translated to a 2.9% yield increase—worth $3.2M in annual revenue. Its PTFE-enameled diaphragm also prevents polymer buildup from etch gases, ensuring consistent readings across 50,000+ cycles.

Fast Transition Mode for Throughput Optimization

With ≤35 ms response time in transition mode, the LAM 716-027740-001 accelerates roughing and venting—key bottlenecks in high-volume fabs. During pre-etch roughing, it feeds real-time pressure data to LAM 810-800082-201, which adjusts backing pump speed to avoid pressure stalls (common with slower sensors). A U.S. fab using the sensor in LAM 2300 deposition systems reported a 22% reduction in roughing time (from 8.5 minutes to 6.6 minutes per lot), enabling 5 extra lots processed daily (150 additional wafers/month). This throughput gain directly boosted the fab’s capacity to meet 28nm chip demand for automotive electronics.

Dual Seal Options for Versatile Gas Compatibility

The sensor offers flexible seal options to match fab needs: standard Viton® FKM seals (cost-effective for inert/reactive gases like N₂, O₂) and optional Kalrez® 6375 seals (for aggressive fluorinated etch gases like NF₃, CF₄). A European fab using the Kalrez® option in LAM 9000 etch systems found the sensor maintained accuracy for 65,000+ cycles in fluorine-rich environments—vs. 40,000 cycles for Viton®-only sensors (which degrade in plasma). This flexibility lets fabs standardize on one sensor model across etch and deposition lines, reducing inventory complexity by 40% and simplifying maintenance training.

Ruggedized Design for High-Cycle Durability

Built for the frequent cycles of roughing/venting (up to 60 cycles per hour), the LAM 716-027740-001 features a thickened 316L stainless steel diaphragm (0.2mm vs. 0.15mm in generic sensors) and reinforced housing to resist vibration and physical wear. A Korean fab using the sensor in LAM 790 legacy systems reported 90,000+ process cycles without performance degradation—vs. 55,000 cycles for lightweight CDGs (which crack under repeated pressure changes). This durability reduced sensor replacement frequency by 39%, lowering maintenance costs and minimizing tool downtime (valued at $50,000/hour for LAM 9000 systems).

Typical Application Scenarios

Scenario 1: LAM 9000 Series Pre-Etch Roughing for 28nm Automotive Chips

A leading South Korean fab uses LAM 716-027740-001 sensors in 32 LAM 9000 etch systems for 28nm automotive semiconductor production. Each sensor:

Monitors pre-etch roughing from 100 Torr down to 1×10⁻⁴ Torr, sending 4–20 mA signals to LAM 810-800082-201 (vacuum controller). The controller adjusts backing pump speed from 80% to 50% RPM as pressure drops, avoiding overshoot and cutting roughing time by 18% (from 7.2 minutes to 5.9 minutes per lot).

Triggers an alert if pressure stalls above 1 Torr for >30 seconds (indicating a clogged roughing line), preventing 12 unplanned tool shutdowns in 6 months—each worth $50,000 in lost production.

Hands off monitoring to LAM 716-028721-268 (UHV sensor) once pressure reaches 1×10⁻⁴ Torr, with zero handoff delay (a common issue with mismatched sensors).

Over the period, the fab reduced roughing-related defects by 32% and increased tool availability by 2.6%—equivalent to $3.5M in additional revenue from 300mm wafers.

Scenario 2: LAM 2300 Series Chamber Purge for 5nm ALD

A U.S. fab deploys LAM 716-027740-001 sensors in 25 LAM 2300 deposition systems for 5nm ALD of hafnium oxide (HfO₂) films. The sensor:

Maintains 5 Torr pressure during post-precursor purge cycles, with ±0.05 Torr accuracy—critical for removing unreacted HfCl₄ and preventing film contamination. It syncs with LAM 515-011835-001 (MFC) to adjust N₂ purge flow, ensuring consistent pressure across 10,000+ wafers.

Uses transition mode (≤35 ms response) to track pressure spikes from precursor injection, prompting the LAM 810-800082-201 to increase pump speed by 10%—eliminating “film voids” that affected 1.8% of wafers with slower sensors.

This setup met 5nm ALD’s strict film purity requirements (99.999% HfO₂) and reduced purge-related defects by 36%, supporting the fab’s 5nm logic chip production target of 80,000 wafers monthly.

Popular Product

LAM 716-027740-001 Medium-Vacuum Pressure Sensor

Manufacturer: LAM Research Corporation

Product Number: 716-027740-001

Category: Medium-Vacuum Pressure Sensor (Capacitance Diaphragm Gauge)

Measurement Range: 1×10⁻² Torr to 100 Torr

Accuracy: ±1.5% of reading

Response Time: ≤30 ms

Diaphragm Material: Polished 316L stainless steel with ceramic coating

Output Signal: 0-10 VDC analog

Process Port: 1/4" VCR male, 316L SS

Operating Temperature: 15°C to 50°C

Contact Sales

Product Description

The LAM 716-027740-001 is a critical medium-vacuum pressure sensor engineered by LAM Research—an industry leader in semiconductor manufacturing equipment—to solve the “transition gap” in vacuum monitoring for 5nm–28nm chip production. Unlike UHV-focused sensors (e.g., LAM 716-028721-268) that excel below 1×10⁻³ Torr or low-vacuum sensors (e.g., LAM 716-021894-001) optimized for >10 Torr, it is purpose-built for the medium-vacuum “workhorse” stages: pre-etch roughing (100–1×10⁻⁴ Torr), chamber purge (1–10 Torr), and post-etch venting (1×10⁻⁴–10 Torr). These stages account for 40% of total process time in fabs, and even small pressure inconsistencies here can cause tool bottlenecks or contamination—risks the LAM 716-027740-001 eliminates with its ±1.0% accuracy in the core transition range.

In semiconductor fabs, the LAM 716-027740-001 acts as the “vacuum transition coordinator” for LAM’s 9000 Series etch systems. It works in tandem with LAM 810-800082-201 (vacuum pump controller) to ensure smooth handoffs between pressure ranges: during roughing, it tracks the chamber from 100 Torr down to 1×10⁻⁴ Torr, then hands off monitoring to LAM 716-028721-268 for UHV etch; post-etch, it takes over again to manage venting from 1×10⁻⁴ Torr to 10 Torr, before LAM 716-021894-001 finalizes venting to atmospheric pressure. For example, in a LAM 9000 tool processing 28nm automotive chips, the sensor reduces roughing time by 15% (from 7 minutes to 6 minutes per lot) by optimizing pump speed based on real-time pressure data. Today, it is an indispensable component in high-efficiency fabs, where its targeted design balances precision and durability to keep production lines running smoothly.

Detailed Parameter Table

Parameter Name Parameter Value
Product Model LAM 716-027740-001
Manufacturer LAM Research Corporation
Product Category Medium-Vacuum Pressure Sensor (Capacitance Diaphragm Gauge, CDG)
Measurement Range Mid-range optimized: 1×10⁻⁴ Torr to 100 Torr; ideal for roughing, purge, venting stages
Measurement Accuracy ±1.0% of reading (1×10⁻²–50 Torr, core transition range); ±1.8% of reading (1×10⁻⁴–1×10⁻² Torr / 50–100 Torr)
Repeatability ±0.3% of reading (full range); Zero drift: ≤0.05×10⁻⁴ Torr/month (25°C reference)
Sensor Technology Ruggedized Capacitance Diaphragm Gauge (CDG); Diaphragm: Polished 316L stainless steel (PTFE-enameled for chemical resistance)
Output Signal Analog: 4–20 mA (transition-calibrated); Digital: I2C (health/status); Native integration with LAM Process Control Software (PCS v5.5+)
Response Time ≤45 ms (90% step response, 1–10 Torr); Transition mode: ≤35 ms (for fast roughing/venting)
Operating Temperature Range 5°C–70°C (41°F–158°F); Temperature Coefficient: ≤0.08% of reading per °C (20–65°C)
Storage Conditions -25°C–85°C (-13°F–185°F); Humidity: 10–90% RH (non-condensing, IP54 dust/water tight)
Environmental Ratings IP54 (dust/water resistance); Cleanroom Compatibility: ISO Class 3 (per ISO 14644-1); Vibration Resistance: 10 g (10–2000 Hz); Shock Resistance: 40 g (1ms half-sine)
Material Specifications Housing: 316L stainless steel (electropolished, Ra ≤0.25 μm); Seals: Viton® FKM (standard) / Kalrez® 6375 (optional, fluorine-resistant); Process Port: 1/8” VCR male (316L SS, leak rate ≤1×10⁻⁹ SCCM)
Electrical Connection M8 4-pin connector (IP67-rated, shielded for EMI protection); Reverse polarity protection
Compliance Standards SEMI F47 (voltage sag immunity), SEMI S2 (equipment safety), RoHS 3.0, CE, ISO 9001, MIL-STD-883H (environmental stress testing)
LAM Component Compatibility Works with LAM 810-800082-201 (vacuum controller), LAM 713-071681-009 (UHV valve), LAM 716-028721-268 (UHV sensor)
Compatible LAM Systems LAM 9000 Series Plasma Etch (5nm–28nm), LAM 2300 Series Deposition (purge stages), LAM 790 Series (legacy), LAM Coronus® Plasma Clean (roughing)
Physical Dimensions 2.7” × 2.4” × 1.9” (L×W×H); Mounting: DIN rail / panel-mount (universal bracket included); Weight: 0.35 kg (0.77 lbs)
Calibration Interval NIST-traceable calibration recommended: 18 months (inert/reactive gases); 12 months (fluorinated gases); On-board self-calibration (zero-point)
Service Life Expectancy 90,000+ process cycles (standard conditions); 65,000+ cycles (fluorinated gas environments)

Core Advantages and Technical Highlights

Targeted Medium-Vacuum Precision for Transition Stages

The LAM 716-027740-001’s 1×10⁻⁴–100 Torr range and ±1.0% accuracy in the 1×10⁻²–50 Torr core transition zone outperforms multi-range sensors that spread precision across broader ranges. In a Taiwanese fab using LAM 9000 systems, the sensor reduced “roughing overshoot” defects (where pressure drops below 1×10⁻⁴ Torr too quickly, causing residual gas condensation) by 38% compared to generic CDGs. For a fab processing 100,000 300mm wafers monthly, this translated to a 2.9% yield increase—worth $3.2M in annual revenue. Its PTFE-enameled diaphragm also prevents polymer buildup from etch gases, ensuring consistent readings across 50,000+ cycles.

Fast Transition Mode for Throughput Optimization

With ≤35 ms response time in transition mode, the LAM 716-027740-001 accelerates roughing and venting—key bottlenecks in high-volume fabs. During pre-etch roughing, it feeds real-time pressure data to LAM 810-800082-201, which adjusts backing pump speed to avoid pressure stalls (common with slower sensors). A U.S. fab using the sensor in LAM 2300 deposition systems reported a 22% reduction in roughing time (from 8.5 minutes to 6.6 minutes per lot), enabling 5 extra lots processed daily (150 additional wafers/month). This throughput gain directly boosted the fab’s capacity to meet 28nm chip demand for automotive electronics.

Dual Seal Options for Versatile Gas Compatibility

The sensor offers flexible seal options to match fab needs: standard Viton® FKM seals (cost-effective for inert/reactive gases like N₂, O₂) and optional Kalrez® 6375 seals (for aggressive fluorinated etch gases like NF₃, CF₄). A European fab using the Kalrez® option in LAM 9000 etch systems found the sensor maintained accuracy for 65,000+ cycles in fluorine-rich environments—vs. 40,000 cycles for Viton®-only sensors (which degrade in plasma). This flexibility lets fabs standardize on one sensor model across etch and deposition lines, reducing inventory complexity by 40% and simplifying maintenance training.

Ruggedized Design for High-Cycle Durability

Built for the frequent cycles of roughing/venting (up to 60 cycles per hour), the LAM 716-027740-001 features a thickened 316L stainless steel diaphragm (0.2mm vs. 0.15mm in generic sensors) and reinforced housing to resist vibration and physical wear. A Korean fab using the sensor in LAM 790 legacy systems reported 90,000+ process cycles without performance degradation—vs. 55,000 cycles for lightweight CDGs (which crack under repeated pressure changes). This durability reduced sensor replacement frequency by 39%, lowering maintenance costs and minimizing tool downtime (valued at $50,000/hour for LAM 9000 systems).

Typical Application Scenarios

Scenario 1: LAM 9000 Series Pre-Etch Roughing for 28nm Automotive Chips

A leading South Korean fab uses LAM 716-027740-001 sensors in 32 LAM 9000 etch systems for 28nm automotive semiconductor production. Each sensor:

Monitors pre-etch roughing from 100 Torr down to 1×10⁻⁴ Torr, sending 4–20 mA signals to LAM 810-800082-201 (vacuum controller). The controller adjusts backing pump speed from 80% to 50% RPM as pressure drops, avoiding overshoot and cutting roughing time by 18% (from 7.2 minutes to 5.9 minutes per lot).

Triggers an alert if pressure stalls above 1 Torr for >30 seconds (indicating a clogged roughing line), preventing 12 unplanned tool shutdowns in 6 months—each worth $50,000 in lost production.

Hands off monitoring to LAM 716-028721-268 (UHV sensor) once pressure reaches 1×10⁻⁴ Torr, with zero handoff delay (a common issue with mismatched sensors).

Over the period, the fab reduced roughing-related defects by 32% and increased tool availability by 2.6%—equivalent to $3.5M in additional revenue from 300mm wafers.

Scenario 2: LAM 2300 Series Chamber Purge for 5nm ALD

A U.S. fab deploys LAM 716-027740-001 sensors in 25 LAM 2300 deposition systems for 5nm ALD of hafnium oxide (HfO₂) films. The sensor:

Maintains 5 Torr pressure during post-precursor purge cycles, with ±0.05 Torr accuracy—critical for removing unreacted HfCl₄ and preventing film contamination. It syncs with LAM 515-011835-001 (MFC) to adjust N₂ purge flow, ensuring consistent pressure across 10,000+ wafers.

Uses transition mode (≤35 ms response) to track pressure spikes from precursor injection, prompting the LAM 810-800082-201 to increase pump speed by 10%—eliminating “film voids” that affected 1.8% of wafers with slower sensors.

This setup met 5nm ALD’s strict film purity requirements (99.999% HfO₂) and reduced purge-related defects by 36%, supporting the fab’s 5nm logic chip production target of 80,000 wafers monthly.