Honeywell 10016/E/1 FSC Ethernet Module
Manufacturer:Honeywell
Product Number:10016/E/1
Product Type:FSC Ethernet Module
Origin:USA
Dimensions:40 x 185 x 128 mm
Weight:0.36 kg
Views:59
Payment Methods:T/T, PayPal, Western Union
Condition:New & In Stock
Warranty:1 Year
Lead Time:1-3 Working Days
Certificate:COO
Courier partners:DHL, UPS, TNT, FedEx and EMS.
Business hours:7*24
Product Description
The Honeywell 10016/E/1 FSC Ethernet Module is a key communication interface used in the Honeywell FSC (Fail Safe Controller) system. It provides Ethernet connectivity between the FSC system and external supervisory systems or networks, enabling high-speed and secure data exchange. Designed for robust industrial environments, this module ensures reliable and continuous operation in critical safety and control applications.
Technical Specifications
| Parameter | Details |
|---|---|
| Product Model | 10016/E/1 |
| Function | Ethernet Communication Module |
| Communication Interface | 10/100 Mbps Ethernet |
| Supported Protocols | TCP/IP, Modbus TCP |
| Power Supply | 5 VDC (powered from base) |
| Mounting Type | Rack-mounted (FSC system rack) |
| Operating Temperature | 0°C to 60°C |
| Storage Temperature | -40°C to 85°C |
| Relative Humidity | 5% to 95% (non-condensing) |
| Dimensions (W x H x D) | 40 x 185 x 128 mm |
| Weight | 0.36 kg |
| Certifications | CE, CSA, FM Class 1 Div 2 |
Applications
-
Safety-critical process control in petrochemical plants
-
Emergency shutdown (ESD) systems
-
Burner management systems (BMS)
-
Fire and gas detection systems
-
High-integrity pressure protection systems (HIPPS)
Advantages
-
Reliable Ethernet communication for safety systems
-
Seamless integration with supervisory control systems
-
Fast and secure data exchange
-
Enhanced diagnostics and data monitoring
-
Compact design for space-constrained racks
-
Certified for use in hazardous industrial environments
Frequently Asked Questions (FAQ)
Q1: What is the primary function of the 10016/E/1 Ethernet Module?
A1: It provides Ethernet communication between the FSC system and external networks using standard protocols like TCP/IP.
Q2: Can this module be hot-swapped?
A2: No, power must be removed before replacing or installing the module to ensure system safety.
Q3: Is this module suitable for hazardous area use?
A3: Yes, it meets certifications including FM Class 1 Div 2 for hazardous industrial locations.
Q4: Which communication protocols are supported?
A4: It supports TCP/IP and Modbus TCP for reliable data communication.
Q5: Can it be used in non-Honeywell systems?
A5: No, it is specifically designed for use with Honeywell FSC systems only.
Q6: What is the maximum supported speed of Ethernet communication?
A6: It supports up to 100 Mbps Ethernet connectivity.
Q7: Is it compatible with Honeywell Safety Manager?
A7: No, it is designed for use with the FSC (Fail Safe Controller) platform, not Safety Manager.
Q8: How is the module powered?
A8: It is powered through the FSC base chassis with a 5 VDC supply.
Q9: What diagnostics are available through this module?
A9: The module provides LED indicators and network status information to aid in diagnostics.
Q10: Is firmware upgrade possible via Ethernet?
A10: No, firmware upgrades must be done through the designated engineering tools, not over Ethernet.
Honeywell 10016/E/1 FSC Ethernet Module
Manufacturer:Honeywell
Product Number:10016/E/1
Product Type:FSC Ethernet Module
Origin:USA
Dimensions:40 x 185 x 128 mm
Weight:0.36 kg
Views:59
Payment Methods:T/T, PayPal, Western Union
Condition:New & In Stock
Warranty:1 Year
Lead Time:1-3 Working Days
Certificate:COO
Courier partners:DHL, UPS, TNT, FedEx and EMS.
Business hours:7*24
Product Description
The Honeywell 10016/E/1 FSC Ethernet Module is a key communication interface used in the Honeywell FSC (Fail Safe Controller) system. It provides Ethernet connectivity between the FSC system and external supervisory systems or networks, enabling high-speed and secure data exchange. Designed for robust industrial environments, this module ensures reliable and continuous operation in critical safety and control applications.
Technical Specifications
| Parameter | Details |
|---|---|
| Product Model | 10016/E/1 |
| Function | Ethernet Communication Module |
| Communication Interface | 10/100 Mbps Ethernet |
| Supported Protocols | TCP/IP, Modbus TCP |
| Power Supply | 5 VDC (powered from base) |
| Mounting Type | Rack-mounted (FSC system rack) |
| Operating Temperature | 0°C to 60°C |
| Storage Temperature | -40°C to 85°C |
| Relative Humidity | 5% to 95% (non-condensing) |
| Dimensions (W x H x D) | 40 x 185 x 128 mm |
| Weight | 0.36 kg |
| Certifications | CE, CSA, FM Class 1 Div 2 |
Applications
-
Safety-critical process control in petrochemical plants
-
Emergency shutdown (ESD) systems
-
Burner management systems (BMS)
-
Fire and gas detection systems
-
High-integrity pressure protection systems (HIPPS)
Advantages
-
Reliable Ethernet communication for safety systems
-
Seamless integration with supervisory control systems
-
Fast and secure data exchange
-
Enhanced diagnostics and data monitoring
-
Compact design for space-constrained racks
-
Certified for use in hazardous industrial environments
Frequently Asked Questions (FAQ)
Q1: What is the primary function of the 10016/E/1 Ethernet Module?
A1: It provides Ethernet communication between the FSC system and external networks using standard protocols like TCP/IP.
Q2: Can this module be hot-swapped?
A2: No, power must be removed before replacing or installing the module to ensure system safety.
Q3: Is this module suitable for hazardous area use?
A3: Yes, it meets certifications including FM Class 1 Div 2 for hazardous industrial locations.
Q4: Which communication protocols are supported?
A4: It supports TCP/IP and Modbus TCP for reliable data communication.
Q5: Can it be used in non-Honeywell systems?
A5: No, it is specifically designed for use with Honeywell FSC systems only.
Q6: What is the maximum supported speed of Ethernet communication?
A6: It supports up to 100 Mbps Ethernet connectivity.
Q7: Is it compatible with Honeywell Safety Manager?
A7: No, it is designed for use with the FSC (Fail Safe Controller) platform, not Safety Manager.
Q8: How is the module powered?
A8: It is powered through the FSC base chassis with a 5 VDC supply.
Q9: What diagnostics are available through this module?
A9: The module provides LED indicators and network status information to aid in diagnostics.
Q10: Is firmware upgrade possible via Ethernet?
A10: No, firmware upgrades must be done through the designated engineering tools, not over Ethernet.
Need a Custom Automation Solution?
Our team of experts can design and implement a tailored automation system to meet your specific requirements.