Our Products
Comprehensive industrial automation solutions for global industries
Contact us
If you are interested in our products and want to know more details,please Contact us,we will reply you as soon as we can.
General Electric 8602-FT-ST Fiber Optic Transmitter Module
Manufacturer:GE Fanuc
Product Number:8602-FT-ST
Product Type:Fiber Optic Transmitter Module
Origin:USA
Dimensions:110 mm × 25 mm × 75 mm
Weight:0.15 kg
Views:113
Payment Methods:T/T, PayPal, Western Union
Condition:New & In Stock
Warranty:1 Year
Lead Time:1-3 Working Days
Certificate:COO
Courier partners:DHL, UPS, TNT, FedEx and EMS.
Business hours:7*24
Product Description
The GE Bently Nevada 8602-FT-ST Fiber Optic Transmitter Module is designed for high-reliability signal distribution within advanced machine protection and condition monitoring architectures. From a system-integration perspective, the 8602-FT-ST acts as the optical interface that bridges monitoring racks, communication processors, and remote acquisition units, providing long-distance, noise-immune connectivity across industrial environments.

The ST-type optical connector offers mechanical robustness and consistent coupling performance, making the module well-suited for environments where vibration, electromagnetic interference, or extended cable runs would compromise traditional copper-based links.
Technical Specifications
| Parameter | Description |
|---|---|
| Model Number | 8602-FT-ST |
| Brand | GE Bently Nevada |
| Module Type | Fiber Optic Transmitter Module |
| Connector Type | ST (twist-lock multimode optical connector) |
| Transmission Medium | Multimode fiber |
| Nominal Wavelength | 820–850 nm (typical multimode LED transmission) |
| Transmission Distance | Up to 2 km (fiber and installation dependent) |
| Power Supply | 24 VDC nominal |
| Power Consumption | Approx. 80–100 mA |
| Compatible Systems | Bently Nevada 3500 Series, 3300 legacy architectures, remote communication units |
| Operating Temperature | –20°C to +65°C |
| Storage Temperature | –40°C to +85°C |
| Dimensions (H × W × D) | 110 mm × 25 mm × 75 mm |
| Weight | ≈ 0.15 kg |
| Mounting Method | Panel or DIN-rail (via installation kit) |
Applications / Use Scenarios
-
Long-distance communication between distributed Bently Nevada monitoring stations
-
Optical link between 3500/22M communication gateways and remote racks
-
Machine protection systems requiring electrical isolation
-
Turbine, compressor, and rotating machinery diagnostic networks
-
Sites where EMI levels prohibit copper-based communication
-
Expansion of existing condition monitoring infrastructure using fiber pathways
Advantages / Engineering Benefits
-
Strong immunity to electromagnetic interference, essential for high-power industrial machinery
-
Long-range signal distribution with stable optical output
-
Mechanical reliability due to ST locking mechanism
-
Simplified integration into both legacy and modern Bently Nevada systems
-
Compact design that fits system expansion projects with tight panel space
-
Electrical isolation improving overall system safety and diagnostic quality
FAQs
-
What communication format does the 8602-FT-ST support?
It transmits digital monitoring signals compatible with Bently Nevada system protocols.
-
Does it work with multimode fiber?
Yes, the module is optimized for standard industrial multimode fiber.
-
Can the module be used in mixed copper/fiber architectures?
Yes, it is often used to transition from copper rack connections to long-distance optical links.
-
Is the ST connector field-serviceable?
The connector can be cleaned and inspected but is not internally serviceable.
-
What is the typical optical wavelength?
Between 820 and 850 nm, standard for industrial LED transmitters.
-
Does it require a dedicated 24 VDC supply?
Yes, stable 24 VDC input is required for proper operation.
-
What temperature range can it handle?
–20°C to +65°C in operation.
-
Can it be mounted directly on a DIN rail?
Yes, with the appropriate mounting adapter.
-
Is there any electrical connection to the receiving module?
No—communication is entirely optical, providing full isolation.
-
Does cable quality affect transmission distance?
Yes, fiber grade, connector polishing, and installation quality influence achievable range.
General Electric 8602-FT-ST Fiber Optic Transmitter Module
Manufacturer:GE Fanuc
Product Number:8602-FT-ST
Product Type:Fiber Optic Transmitter Module
Origin:USA
Dimensions:110 mm × 25 mm × 75 mm
Weight:0.15 kg
Views:113
Payment Methods:T/T, PayPal, Western Union
Condition:New & In Stock
Warranty:1 Year
Lead Time:1-3 Working Days
Certificate:COO
Courier partners:DHL, UPS, TNT, FedEx and EMS.
Business hours:7*24
Product Description
The GE Bently Nevada 8602-FT-ST Fiber Optic Transmitter Module is designed for high-reliability signal distribution within advanced machine protection and condition monitoring architectures. From a system-integration perspective, the 8602-FT-ST acts as the optical interface that bridges monitoring racks, communication processors, and remote acquisition units, providing long-distance, noise-immune connectivity across industrial environments.

The ST-type optical connector offers mechanical robustness and consistent coupling performance, making the module well-suited for environments where vibration, electromagnetic interference, or extended cable runs would compromise traditional copper-based links.
Technical Specifications
| Parameter | Description |
|---|---|
| Model Number | 8602-FT-ST |
| Brand | GE Bently Nevada |
| Module Type | Fiber Optic Transmitter Module |
| Connector Type | ST (twist-lock multimode optical connector) |
| Transmission Medium | Multimode fiber |
| Nominal Wavelength | 820–850 nm (typical multimode LED transmission) |
| Transmission Distance | Up to 2 km (fiber and installation dependent) |
| Power Supply | 24 VDC nominal |
| Power Consumption | Approx. 80–100 mA |
| Compatible Systems | Bently Nevada 3500 Series, 3300 legacy architectures, remote communication units |
| Operating Temperature | –20°C to +65°C |
| Storage Temperature | –40°C to +85°C |
| Dimensions (H × W × D) | 110 mm × 25 mm × 75 mm |
| Weight | ≈ 0.15 kg |
| Mounting Method | Panel or DIN-rail (via installation kit) |
Applications / Use Scenarios
-
Long-distance communication between distributed Bently Nevada monitoring stations
-
Optical link between 3500/22M communication gateways and remote racks
-
Machine protection systems requiring electrical isolation
-
Turbine, compressor, and rotating machinery diagnostic networks
-
Sites where EMI levels prohibit copper-based communication
-
Expansion of existing condition monitoring infrastructure using fiber pathways
Advantages / Engineering Benefits
-
Strong immunity to electromagnetic interference, essential for high-power industrial machinery
-
Long-range signal distribution with stable optical output
-
Mechanical reliability due to ST locking mechanism
-
Simplified integration into both legacy and modern Bently Nevada systems
-
Compact design that fits system expansion projects with tight panel space
-
Electrical isolation improving overall system safety and diagnostic quality
FAQs
-
What communication format does the 8602-FT-ST support?
It transmits digital monitoring signals compatible with Bently Nevada system protocols.
-
Does it work with multimode fiber?
Yes, the module is optimized for standard industrial multimode fiber.
-
Can the module be used in mixed copper/fiber architectures?
Yes, it is often used to transition from copper rack connections to long-distance optical links.
-
Is the ST connector field-serviceable?
The connector can be cleaned and inspected but is not internally serviceable.
-
What is the typical optical wavelength?
Between 820 and 850 nm, standard for industrial LED transmitters.
-
Does it require a dedicated 24 VDC supply?
Yes, stable 24 VDC input is required for proper operation.
-
What temperature range can it handle?
–20°C to +65°C in operation.
-
Can it be mounted directly on a DIN rail?
Yes, with the appropriate mounting adapter.
-
Is there any electrical connection to the receiving module?
No—communication is entirely optical, providing full isolation.
-
Does cable quality affect transmission distance?
Yes, fiber grade, connector polishing, and installation quality influence achievable range.
Need a Custom Automation Solution?
Our team of experts can design and implement a tailored automation system to meet your specific requirements.

Loading comments...