Yokogawa SNB10D-215/CU2T Safety Node Unit
Yokogawa SNB10D-215/CU2T Safety Node Unit
Yokogawa SNB10D-215/CU2T Safety Node Unit
Yokogawa SNB10D-215/CU2T Safety Node Unit
Popular Product

Yokogawa SNB10D-215/CU2T Safety Node Unit


Manufacturer:Yokogawa

Product Number:SNB10D-215/CU2T

Product Type:Safety Node Unit

Origin:Japan

Dimensions:482.6 x 221.5 x 205 mm

Weight:5.9 kg

Views:33

Payment Methods:T/T, PayPal, Western Union

Condition:New & In Stock

Warranty:1 Year

Lead Time:1-3 Working Days

Certificate:COO

Courier partners:DHL, UPS, TNT, FedEx and EMS.

Business hours:7*24

Contact Sales

Product Description

The Yokogawa SNB10D-215/CU2T Safety Node Unit is a high-performance, rack-mountable module designed for safety instrumented systems (SIS). It functions as an interface between field devices and safety control units, ensuring reliable communication and power distribution. The unit supports redundant power configuration and operates in harsh industrial environments, conforming to ISA Standard G3.

Technical Specifications

Parameter Specification
Model SNB10D-215/CU2T
Power Supply Dual-redundant, 100–120 V AC
Communication ESB (Ethernet Safety Bus)
Mounting 19-inch rack, 4 M5 screws
Dimensions 482.6 x 221.5 x 205 mm
Weight 5.9 kg
Operating Temperature -20°C to 70°C
Conformance ISA Standard G3
Option Code CU2T: Connector Unit with Terminator for ESB Bus

Applications

  • Integration in safety instrumented systems (SIS)

  • Connection to Yokogawa S2SC70S/D or SSC60S/D safety controllers

  • Interface for field I/O modules in process control environments

  • Industrial safety monitoring in chemical, petrochemical, and power plants

Advantages

  • High reliability through dual-redundant power configuration

  • Rack-mountable design for compact and organized installation

  • Broad operational temperature range suitable for harsh environments

  • Conforms to ISA G3, ensuring robust industrial compliance

  • Supports a wide range of I/O modules for flexible system expansion

FAQ

1. What is the main function of the SNB10D-215/CU2T?

It acts as an interface between field devices and safety control units, facilitating communication and power distribution.

2. Can the unit operate in high-temperature environments?

Yes, it is designed to operate between -20°C and 70°C.

3. Does it support redundant power supply?

Yes, it has a dual-redundant power configuration for enhanced reliability.

4. What communication protocol does it use?

The unit supports ESB (Ethernet Safety Bus) for communication.

5. What types of field devices can it interface with?

It can interface with a variety of I/O modules connected to safety instrumented systems.

6. Is the unit rack-mountable?

Yes, it is designed for 19-inch rack mounting with 4 M5 screws.

7. What standards does it conform to?

It meets ISA Standard G3 for environmental conditions.

8. What is the weight of the unit?

The unit weighs 5.9 kg.

9. Can it be used with Yokogawa SSC60S/D controllers?

Yes, it is compatible with SSC60S/D and S2SC70S/D safety controllers.

10. What does the CU2T option code indicate?

CU2T indicates a Connector Unit with Terminator for the ESB Bus.

Popular Product

Yokogawa SNB10D-215/CU2T Safety Node Unit

Manufacturer:Yokogawa

Product Number:SNB10D-215/CU2T

Product Type:Safety Node Unit

Origin:Japan

Dimensions:482.6 x 221.5 x 205 mm

Weight:5.9 kg

Views:33

Payment Methods:T/T, PayPal, Western Union

Condition:New & In Stock

Warranty:1 Year

Lead Time:1-3 Working Days

Certificate:COO

Courier partners:DHL, UPS, TNT, FedEx and EMS.

Business hours:7*24

Contact Sales

Product Description

The Yokogawa SNB10D-215/CU2T Safety Node Unit is a high-performance, rack-mountable module designed for safety instrumented systems (SIS). It functions as an interface between field devices and safety control units, ensuring reliable communication and power distribution. The unit supports redundant power configuration and operates in harsh industrial environments, conforming to ISA Standard G3.

Technical Specifications

Parameter Specification
Model SNB10D-215/CU2T
Power Supply Dual-redundant, 100–120 V AC
Communication ESB (Ethernet Safety Bus)
Mounting 19-inch rack, 4 M5 screws
Dimensions 482.6 x 221.5 x 205 mm
Weight 5.9 kg
Operating Temperature -20°C to 70°C
Conformance ISA Standard G3
Option Code CU2T: Connector Unit with Terminator for ESB Bus

Applications

  • Integration in safety instrumented systems (SIS)

  • Connection to Yokogawa S2SC70S/D or SSC60S/D safety controllers

  • Interface for field I/O modules in process control environments

  • Industrial safety monitoring in chemical, petrochemical, and power plants

Advantages

  • High reliability through dual-redundant power configuration

  • Rack-mountable design for compact and organized installation

  • Broad operational temperature range suitable for harsh environments

  • Conforms to ISA G3, ensuring robust industrial compliance

  • Supports a wide range of I/O modules for flexible system expansion

FAQ

1. What is the main function of the SNB10D-215/CU2T?

It acts as an interface between field devices and safety control units, facilitating communication and power distribution.

2. Can the unit operate in high-temperature environments?

Yes, it is designed to operate between -20°C and 70°C.

3. Does it support redundant power supply?

Yes, it has a dual-redundant power configuration for enhanced reliability.

4. What communication protocol does it use?

The unit supports ESB (Ethernet Safety Bus) for communication.

5. What types of field devices can it interface with?

It can interface with a variety of I/O modules connected to safety instrumented systems.

6. Is the unit rack-mountable?

Yes, it is designed for 19-inch rack mounting with 4 M5 screws.

7. What standards does it conform to?

It meets ISA Standard G3 for environmental conditions.

8. What is the weight of the unit?

The unit weighs 5.9 kg.

9. Can it be used with Yokogawa SSC60S/D controllers?

Yes, it is compatible with SSC60S/D and S2SC70S/D safety controllers.

10. What does the CU2T option code indicate?

CU2T indicates a Connector Unit with Terminator for the ESB Bus.