Comprehensive industrial automation solutions for global industries
If you are interested in our products and want to know more details,please Contact us,we will reply you as soon as we can.
Contact Support
Manufacturer:ABB
Product Number:NETA-21 3AUA0000093675
Product Type:Remote monitoring tools
Origin:Sweden
Dimensions:96 × 96 × 85 mm
Weight:0.5 kg
Views:32
Payment Methods:T/T, PayPal, Western Union
Condition:New & In Stock
Warranty:1 Year
Lead Time:1-3 Working Days
Certificate:COO
Courier partners:DHL, UPS, TNT, FedEx and EMS.
Business hours:7*24
The ABB NETA-21 is a versatile and reliable network analyzer designed for monitoring and analyzing electrical parameters in power distribution systems. It is widely used in industrial, commercial, and utility applications to ensure efficient energy management and system protection.
| Parameter | Specification |
|---|---|
| Model Number | NETA-21 (3AUA0000093675) |
| Input Voltage | 100-480V AC (phase-to-phase) |
| Frequency Range | 45-65 Hz |
| Current Input | 1A or 5A (configurable) |
| Power Consumption | <5 VA |
| Communication | RS-485 (Modbus RTU protocol) |
| Display | LCD with backlight |
| Measurement Accuracy | Voltage: ±0.5%, Current: ±1%, Power: ±1% |
| Dimensions (W x H x D) | 96 x 96 x 65 mm |
| Weight | 0.5 kg |
| Operating Temperature | -10°C to +55°C |
| Protection Class | IP40 (front panel) |
| Certifications | CE, UL, IEC 61010 |
The ABB NETA-21 is suitable for a wide range of applications, including:
Industrial Power Monitoring: Real-time analysis of electrical parameters in manufacturing plants.
Energy Management Systems: Integration into SCADA and BMS for efficient energy usage tracking.
Renewable Energy Systems: Monitoring solar/wind power inverters and grid connections.
Commercial Buildings: Load profiling and power quality analysis in offices and malls.
Utility Substations: Voltage and current monitoring for grid stability.
High Accuracy: Precise measurements for voltage, current, power, and energy.
Compact Design: Space-saving 96×96 mm panel-mounted form factor.
Easy Integration: Supports Modbus RTU for seamless connectivity with control systems.
Robust Construction: Durable housing with IP40 protection for harsh environments.
User-Friendly Interface: Clear LCD display with intuitive navigation.
Wide Voltage Range: Compatible with 100-480V AC systems.
What communication protocols does the NETA-21 support?
The device supports Modbus RTU over RS-485.
Can the NETA-21 measure harmonics?
No, it focuses on basic electrical parameters (voltage, current, power, energy).
Is the NETA-21 suitable for DC systems?
No, it is designed for AC systems only.
What is the typical response time for measurements?
Updates are provided every 1-2 seconds.
Does it require external power?
No, it is self-powered from the measured voltage inputs.
Can multiple NETA-21 units be networked?
Yes, up to 32 devices can be connected via RS-485.
What is the warranty period?
ABB provides a standard 1-year warranty.
Is calibration required periodically?
Yes, recommended every 2-3 years for optimal accuracy.
Can it be used in outdoor installations?
No, it is rated for indoor use (IP40).
How do I configure the current transformer (CT) ratio?
Settings can be adjusted via the front panel or Modbus commands.
Manufacturer:ABB
Product Number:NETA-21 3AUA0000093675
Product Type:Remote monitoring tools
Origin:Sweden
Dimensions:96 × 96 × 85 mm
Weight:0.5 kg
Views:32
Payment Methods:T/T, PayPal, Western Union
Condition:New & In Stock
Warranty:1 Year
Lead Time:1-3 Working Days
Certificate:COO
Courier partners:DHL, UPS, TNT, FedEx and EMS.
Business hours:7*24
The ABB NETA-21 is a versatile and reliable network analyzer designed for monitoring and analyzing electrical parameters in power distribution systems. It is widely used in industrial, commercial, and utility applications to ensure efficient energy management and system protection.
| Parameter | Specification |
|---|---|
| Model Number | NETA-21 (3AUA0000093675) |
| Input Voltage | 100-480V AC (phase-to-phase) |
| Frequency Range | 45-65 Hz |
| Current Input | 1A or 5A (configurable) |
| Power Consumption | <5 VA |
| Communication | RS-485 (Modbus RTU protocol) |
| Display | LCD with backlight |
| Measurement Accuracy | Voltage: ±0.5%, Current: ±1%, Power: ±1% |
| Dimensions (W x H x D) | 96 x 96 x 65 mm |
| Weight | 0.5 kg |
| Operating Temperature | -10°C to +55°C |
| Protection Class | IP40 (front panel) |
| Certifications | CE, UL, IEC 61010 |
The ABB NETA-21 is suitable for a wide range of applications, including:
Industrial Power Monitoring: Real-time analysis of electrical parameters in manufacturing plants.
Energy Management Systems: Integration into SCADA and BMS for efficient energy usage tracking.
Renewable Energy Systems: Monitoring solar/wind power inverters and grid connections.
Commercial Buildings: Load profiling and power quality analysis in offices and malls.
Utility Substations: Voltage and current monitoring for grid stability.
High Accuracy: Precise measurements for voltage, current, power, and energy.
Compact Design: Space-saving 96×96 mm panel-mounted form factor.
Easy Integration: Supports Modbus RTU for seamless connectivity with control systems.
Robust Construction: Durable housing with IP40 protection for harsh environments.
User-Friendly Interface: Clear LCD display with intuitive navigation.
Wide Voltage Range: Compatible with 100-480V AC systems.
What communication protocols does the NETA-21 support?
The device supports Modbus RTU over RS-485.
Can the NETA-21 measure harmonics?
No, it focuses on basic electrical parameters (voltage, current, power, energy).
Is the NETA-21 suitable for DC systems?
No, it is designed for AC systems only.
What is the typical response time for measurements?
Updates are provided every 1-2 seconds.
Does it require external power?
No, it is self-powered from the measured voltage inputs.
Can multiple NETA-21 units be networked?
Yes, up to 32 devices can be connected via RS-485.
What is the warranty period?
ABB provides a standard 1-year warranty.
Is calibration required periodically?
Yes, recommended every 2-3 years for optimal accuracy.
Can it be used in outdoor installations?
No, it is rated for indoor use (IP40).
How do I configure the current transformer (CT) ratio?
Settings can be adjusted via the front panel or Modbus commands.
Our team of experts can design and implement a tailored automation system to meet your specific requirements.