Our Products

Comprehensive industrial automation solutions for global industries

Home / Honeywell / Honeywell RM7895A1014
Product Categories
Product Categories

Contact us

If you are interested in our products and want to know more details,please Contact us,we will reply you as soon as we can.

Honeywell RM7895A1014 Burner Control
Honeywell RM7895A1014 Burner Control
Honeywell RM7895A1014 Burner Control
Honeywell RM7895A1014 Burner Control
Popular Product

Honeywell RM7895A1014 Burner Control


Manufacturer:Honeywell

Product Number:RM7895A1014

Product Type:Burner Control

Origin:USA

Dimensions:127 x 127 x 133 mm

Weight:0.83 kg

Views:45

Payment Methods:T/T, PayPal, Western Union

Condition:New & In Stock

Warranty:1 Year

Lead Time:1-3 Working Days

Certificate:COO

Courier partners:DHL, UPS, TNT, FedEx and EMS.

Business hours:7*24

Contact Sales

Product Description

The Honeywell RM7895A1014 is a microprocessor-based burner control relay module designed for automatically fired single-burner gas, oil, or combination fuel applications. It ensures safe and reliable burner sequencing, flame supervision, system diagnostics, and status indication. This module forms part of Honeywell’s 7800 Series, known for its safety and operational flexibility.

Technical Specifications

Parameter Specification
Operating Voltage 120 VAC (+10/-15%), 50/60 Hz
Power Consumption 10 W max
Maximum Connected Load 2000 VA
Operating Temperature -40°F to +140°F (-40°C to +60°C)
Storage Temperature -60°F to +150°F (-40°C to +66°C)
Humidity 85% RH continuous, non-condensing
Dimensions 127 x 127 x 133 mm
Weight 0.83 kg

Applications

  • Industrial boilers

  • Commercial heating systems

  • Process burners

  • Gas and oil-fired single-burner equipment

  • Combustion systems requiring enhanced safety and diagnostics

Advantages

  • Microprocessor-controlled for improved safety and reliability

  • Dynamic self-checking flame supervision

  • Optional communication interfaces for remote monitoring

  • Nonvolatile memory retains status after power loss

  • First-out annunciation for quick fault identification

  • Tamper-resistant design with internal hardware monitoring

  • Flexible mounting options (panel or wall mount)

Frequently Asked Questions (FAQ)

Q1: What type of burners is the RM7895A1014 suitable for?

A1: It is designed for gas, oil, or combination fuel single-burner applications.

Q2: Does the module retain fault history after a power loss?

A2: Yes, it has nonvolatile memory to retain status and history.

Q3: What is the input voltage requirement?

A3: 120 VAC with ±10% tolerance at 50 or 60 Hz.

Q4: Can it be used in high-humidity environments?

A4: Yes, up to 85% RH, non-condensing.

Q5: Does it support remote reset and monitoring?

A5: Yes, with optional remote reset and communication modules.

Q6: Is it compatible with flame rod and UV flame detectors?

A6: Yes, it supports both types with appropriate amplifiers.

Q7: What is the flame failure response time?

A7: 0.8 or 3 seconds depending on the amplifier used.

Q8: What safety checks does it include?

A8: Interlock checks, self-diagnostics, dynamic flame checks, and more.

Q9: Can it handle delayed main valve operation?

A9: Yes, delayed main valve output is supported.

Q10: Is it certified by safety agencies?

A10: Yes, it is UL listed, CSA certified, and FM approved.

Popular Product

Honeywell RM7895A1014 Burner Control

Manufacturer:Honeywell

Product Number:RM7895A1014

Product Type:Burner Control

Origin:USA

Dimensions:127 x 127 x 133 mm

Weight:0.83 kg

Views:45

Payment Methods:T/T, PayPal, Western Union

Condition:New & In Stock

Warranty:1 Year

Lead Time:1-3 Working Days

Certificate:COO

Courier partners:DHL, UPS, TNT, FedEx and EMS.

Business hours:7*24

Contact Sales

Product Description

The Honeywell RM7895A1014 is a microprocessor-based burner control relay module designed for automatically fired single-burner gas, oil, or combination fuel applications. It ensures safe and reliable burner sequencing, flame supervision, system diagnostics, and status indication. This module forms part of Honeywell’s 7800 Series, known for its safety and operational flexibility.

Technical Specifications

Parameter Specification
Operating Voltage 120 VAC (+10/-15%), 50/60 Hz
Power Consumption 10 W max
Maximum Connected Load 2000 VA
Operating Temperature -40°F to +140°F (-40°C to +60°C)
Storage Temperature -60°F to +150°F (-40°C to +66°C)
Humidity 85% RH continuous, non-condensing
Dimensions 127 x 127 x 133 mm
Weight 0.83 kg

Applications

  • Industrial boilers

  • Commercial heating systems

  • Process burners

  • Gas and oil-fired single-burner equipment

  • Combustion systems requiring enhanced safety and diagnostics

Advantages

  • Microprocessor-controlled for improved safety and reliability

  • Dynamic self-checking flame supervision

  • Optional communication interfaces for remote monitoring

  • Nonvolatile memory retains status after power loss

  • First-out annunciation for quick fault identification

  • Tamper-resistant design with internal hardware monitoring

  • Flexible mounting options (panel or wall mount)

Frequently Asked Questions (FAQ)

Q1: What type of burners is the RM7895A1014 suitable for?

A1: It is designed for gas, oil, or combination fuel single-burner applications.

Q2: Does the module retain fault history after a power loss?

A2: Yes, it has nonvolatile memory to retain status and history.

Q3: What is the input voltage requirement?

A3: 120 VAC with ±10% tolerance at 50 or 60 Hz.

Q4: Can it be used in high-humidity environments?

A4: Yes, up to 85% RH, non-condensing.

Q5: Does it support remote reset and monitoring?

A5: Yes, with optional remote reset and communication modules.

Q6: Is it compatible with flame rod and UV flame detectors?

A6: Yes, it supports both types with appropriate amplifiers.

Q7: What is the flame failure response time?

A7: 0.8 or 3 seconds depending on the amplifier used.

Q8: What safety checks does it include?

A8: Interlock checks, self-diagnostics, dynamic flame checks, and more.

Q9: Can it handle delayed main valve operation?

A9: Yes, delayed main valve output is supported.

Q10: Is it certified by safety agencies?

A10: Yes, it is UL listed, CSA certified, and FM approved.

Related Products