Comprehensive industrial automation solutions for global industries
If you are interested in our products and want to know more details,please Contact us,we will reply you as soon as we can.
Contact Support
Manufacturer:Honeywell
Product Number:RM7865C1007
Product Type:Burner Control
Origin:USA
Dimensions:127 x 127 x 133 mm
Weight:0.822 kg
Views:44
Payment Methods:T/T, PayPal, Western Union
Condition:New & In Stock
Warranty:1 Year
Lead Time:1-3 Working Days
Certificate:COO
Courier partners:DHL, UPS, TNT, FedEx and EMS.
Business hours:7*24
The Honeywell RM7865C1007 is a microprocessor-based relay module designed to control and monitor Fulton Pulse boilers. It offers enhanced safety, reliability, and diagnostics compared to conventional burner controls. It provides automatic sequencing, flame supervision, system diagnostics, and optional communication interfaces.
| Parameter | Value |
|---|---|
| Model | RM7865C1007 |
| Power Supply | 120 VAC (+10%/-15%), 50/60 Hz |
| Power Consumption | 10 W maximum |
| Maximum Connected Load | 2000 VA |
| Ambient Operating Temperature | -40°C to +60°C |
| Storage Temperature | -40°C to +66°C |
| Humidity | 85% RH, non-condensing |
| Dimensions | 127 × 127 × 133 mm |
| Weight | 0.822 kg |
| Mounting | On Q7800A1013 subbase (required) |
| Safety Standard Compliance | SIL 3 capable, UL listed, FM approved |
Fulton Pulse boilers
Industrial steam and hot water boilers
Burner safety and sequencing control systems
Applications requiring high diagnostic and annunciation capabilities
Retrofit and upgrade of older boiler control systems
Advanced safety monitoring including dynamic self-check and safe-start checks
SIL 3 capable for high-integrity safety applications
Optional remote annunciation and diagnostics
Modular design with plug-in flame amplifiers and display modules
Non-volatile memory retains history and status after power loss
Multiple optional communication and monitoring interfaces
Field-configurable with selectable retry options for ignition
Q1: What is the power supply requirement for RM7865C1007?
A1: It requires 120 VAC (+10%/-15%), 50/60 Hz.
Q2: What is the size and weight of this module?
A2: Dimensions are 127 × 127 × 133 mm, and it weighs 0.822 kg.
Q3: Which boiler type is it designed for?
A3: It is specifically designed for Fulton Pulse boilers.
Q4: Can it operate in low-temperature environments?
A4: Yes, operating temperature range is from -40°C to +60°C.
Q5: Does it support remote diagnostics?
A5: Yes, with optional modules like the Keyboard Display Module and ControlBus™.
Q6: What safety standards does it comply with?
A6: SIL 3 capable, UL listed, and Factory Mutual approved.
Q7: How does it handle power loss?
A7: It has non-volatile memory to retain operation history and status.
Q8: Is the flame amplifier included?
A8: No, compatible plug-in flame amplifiers are ordered separately.
Q9: What is the maximum connected load supported?
A9: It can support up to 2000 VA.
Q10: Is it suitable for high-humidity environments?
A10: Yes, up to 85% RH, non-condensing.
Manufacturer:Honeywell
Product Number:RM7865C1007
Product Type:Burner Control
Origin:USA
Dimensions:127 x 127 x 133 mm
Weight:0.822 kg
Views:44
Payment Methods:T/T, PayPal, Western Union
Condition:New & In Stock
Warranty:1 Year
Lead Time:1-3 Working Days
Certificate:COO
Courier partners:DHL, UPS, TNT, FedEx and EMS.
Business hours:7*24
The Honeywell RM7865C1007 is a microprocessor-based relay module designed to control and monitor Fulton Pulse boilers. It offers enhanced safety, reliability, and diagnostics compared to conventional burner controls. It provides automatic sequencing, flame supervision, system diagnostics, and optional communication interfaces.
| Parameter | Value |
|---|---|
| Model | RM7865C1007 |
| Power Supply | 120 VAC (+10%/-15%), 50/60 Hz |
| Power Consumption | 10 W maximum |
| Maximum Connected Load | 2000 VA |
| Ambient Operating Temperature | -40°C to +60°C |
| Storage Temperature | -40°C to +66°C |
| Humidity | 85% RH, non-condensing |
| Dimensions | 127 × 127 × 133 mm |
| Weight | 0.822 kg |
| Mounting | On Q7800A1013 subbase (required) |
| Safety Standard Compliance | SIL 3 capable, UL listed, FM approved |
Fulton Pulse boilers
Industrial steam and hot water boilers
Burner safety and sequencing control systems
Applications requiring high diagnostic and annunciation capabilities
Retrofit and upgrade of older boiler control systems
Advanced safety monitoring including dynamic self-check and safe-start checks
SIL 3 capable for high-integrity safety applications
Optional remote annunciation and diagnostics
Modular design with plug-in flame amplifiers and display modules
Non-volatile memory retains history and status after power loss
Multiple optional communication and monitoring interfaces
Field-configurable with selectable retry options for ignition
Q1: What is the power supply requirement for RM7865C1007?
A1: It requires 120 VAC (+10%/-15%), 50/60 Hz.
Q2: What is the size and weight of this module?
A2: Dimensions are 127 × 127 × 133 mm, and it weighs 0.822 kg.
Q3: Which boiler type is it designed for?
A3: It is specifically designed for Fulton Pulse boilers.
Q4: Can it operate in low-temperature environments?
A4: Yes, operating temperature range is from -40°C to +60°C.
Q5: Does it support remote diagnostics?
A5: Yes, with optional modules like the Keyboard Display Module and ControlBus™.
Q6: What safety standards does it comply with?
A6: SIL 3 capable, UL listed, and Factory Mutual approved.
Q7: How does it handle power loss?
A7: It has non-volatile memory to retain operation history and status.
Q8: Is the flame amplifier included?
A8: No, compatible plug-in flame amplifiers are ordered separately.
Q9: What is the maximum connected load supported?
A9: It can support up to 2000 VA.
Q10: Is it suitable for high-humidity environments?
A10: Yes, up to 85% RH, non-condensing.
Our team of experts can design and implement a tailored automation system to meet your specific requirements.