Yokogawa RB401/S2 RIO Bus Module
Yokogawa RB401/S2 RIO Bus Module
Yokogawa RB401/S2 RIO Bus Module
Yokogawa RB401/S2 RIO Bus Module
Popular Product

Yokogawa RB401/S2 RIO Bus Module


Manufacturer:Yokogawa

Product Number:RB401/S2

Product Type:RIO Bus Module

Origin:Japan

Dimensions:100 × 25.4 × 20.3 mm

Weight:0.25  kg

Views:44

Payment Methods:T/T, PayPal, Western Union

Condition:New & In Stock

Warranty:1 Year

Lead Time:1-3 Working Days

Certificate:COO

Courier partners:DHL, UPS, TNT, FedEx and EMS.

Business hours:7*24

Contact Sales

Product Description

The Yokogawa RB401/S2 RIO Bus Module is a reliable communication interface used in distributed control systems. It connects remote I/O stations to the main control network, ensuring stable and high-speed data exchange. It is designed to fit into Yokogawa’s CENTUM or ProSafe systems.

Technical Specifications

Parameter Specification
Model RB401/S2
Function RIO Bus Communication Module
Dimensions 100 × 25.4 × 20.3 mm
Weight 0.25 kg
Power Supply 5 VDC (via backplane)
Bus Type Remote I/O Bus
Operating Temperature 0–50 °C
Storage Temperature -20–70 °C
Humidity 5–95% RH, non-condensing
Installation Rack-mounted

Applications

Advantages

  • High reliability and stable communication

  • Compact and lightweight design for easy installation

  • Seamless integration into Yokogawa DCS and SIS platforms

  • Wide operating temperature range

  • Supports high-speed and long-distance remote connections

FAQ

Q1: What is the main function of the RB401/S2?

A1: It connects remote I/O stations to the control system via the RIO bus.

Q2: Is the RB401/S2 compatible with CENTUM VP?

A2: Yes, it is fully compatible with CENTUM VP systems.

Q3: Can it operate in harsh industrial environments?

A3: Yes, it is designed for 0–50 °C and high humidity conditions.

Q4: How is it powered?

A4: It is powered through the system backplane at 5 VDC.

Q5: Is the module hot-swappable?

A5: No, power down the system before replacing the module.

Q6: Does it require specific software configuration?

A6: Yes, it needs to be configured through Yokogawa’s engineering tools.

Q7: What type of signals does it handle?

A7: It handles digital communication over the RIO bus.

Q8: What is the weight of the module?

A8: It weighs approximately 0.25 kg.

Q9: How many modules can be installed in one system?

A9: This depends on the system architecture and backplane capacity.

Q10: Is it resistant to vibration and shock?

A10: Yes, it meets industrial vibration and shock standards.

Popular Product

Yokogawa RB401/S2 RIO Bus Module

Manufacturer:Yokogawa

Product Number:RB401/S2

Product Type:RIO Bus Module

Origin:Japan

Dimensions:100 × 25.4 × 20.3 mm

Weight:0.25  kg

Views:44

Payment Methods:T/T, PayPal, Western Union

Condition:New & In Stock

Warranty:1 Year

Lead Time:1-3 Working Days

Certificate:COO

Courier partners:DHL, UPS, TNT, FedEx and EMS.

Business hours:7*24

Contact Sales

Product Description

The Yokogawa RB401/S2 RIO Bus Module is a reliable communication interface used in distributed control systems. It connects remote I/O stations to the main control network, ensuring stable and high-speed data exchange. It is designed to fit into Yokogawa’s CENTUM or ProSafe systems.

Technical Specifications

Parameter Specification
Model RB401/S2
Function RIO Bus Communication Module
Dimensions 100 × 25.4 × 20.3 mm
Weight 0.25 kg
Power Supply 5 VDC (via backplane)
Bus Type Remote I/O Bus
Operating Temperature 0–50 °C
Storage Temperature -20–70 °C
Humidity 5–95% RH, non-condensing
Installation Rack-mounted

Applications

Advantages

  • High reliability and stable communication

  • Compact and lightweight design for easy installation

  • Seamless integration into Yokogawa DCS and SIS platforms

  • Wide operating temperature range

  • Supports high-speed and long-distance remote connections

FAQ

Q1: What is the main function of the RB401/S2?

A1: It connects remote I/O stations to the control system via the RIO bus.

Q2: Is the RB401/S2 compatible with CENTUM VP?

A2: Yes, it is fully compatible with CENTUM VP systems.

Q3: Can it operate in harsh industrial environments?

A3: Yes, it is designed for 0–50 °C and high humidity conditions.

Q4: How is it powered?

A4: It is powered through the system backplane at 5 VDC.

Q5: Is the module hot-swappable?

A5: No, power down the system before replacing the module.

Q6: Does it require specific software configuration?

A6: Yes, it needs to be configured through Yokogawa’s engineering tools.

Q7: What type of signals does it handle?

A7: It handles digital communication over the RIO bus.

Q8: What is the weight of the module?

A8: It weighs approximately 0.25 kg.

Q9: How many modules can be installed in one system?

A9: This depends on the system architecture and backplane capacity.

Q10: Is it resistant to vibration and shock?

A10: Yes, it meets industrial vibration and shock standards.