Emerson Epro CON041 Eddy Current Signal Converter
Product Number: CON041
Category: Eddy Current Signal Converter
Function: Signal conditioning and conversion for eddy current sensors
Sensor Compatibility: PR642x series eddy current sensors
System Compatibility: MMS 3000/6000 machinery monitoring systems
Application: Converts sensor signals for vibration, position, displacement monitoring
Product Description
Sensor Signal Converter designed for critical turbo machinery applications such as steam, gas and hydro turbines, compressors, pumps and fans to measure radial and axial shaft displacement, position, eccentricity and speed/key.
| Dynamic Performance | |
| Frequency Range (-3 dB) | 0 to 20,000 Hz |
| Rise Time | <15µs |
|
NOTE: Designed for PR6422, PR6423, PR6424, PR6425, PR6426
For Extended Range Use: CON041/91x-xxx PR6425 Requires Extended Range Converter |
|
| Environmental | |
| Operating Temperature Range | -30 to 100°C (-22 to 212°F) |
| Shock and Vibration | 5g @ 60Hz @ 25°C (77°F) |
| Protection Class | IP20 |
| Power & Electrical | |
| Supply Voltage Range | -23Vto -32V (Output Range -4Vto -20V) |
| -21Vto -32V (Output Range -2Vto -18V) | |
| Physical | |
| Housing Material / Weight | PA 6.6 / ~60 grams (2.12 oz) |
| Mounting | Din Rail |
| Connections |
Screw Terminal (Max. 1.5mm2,
Wire-end Sleeves) |
Compliance and Certifications
- CE 2014/30/EU
- 2014/34/EU
- 2011/65/EU
- EN61326-1
- DIN EN 50581
- ATEX EN 60079-0:2009
- EN 60079-11:2012
- IEC-Ex IEC 60079-0:2007-10; Edition 5
- IEC 60079-11:2011; Edition: 6.0
- IEC 60079-26:2006; Edition: 2
- CSA CAN/CSA-C22.2 NO. 0-M91
- CAN/CSA-C22.2 NO. 157-92
- CAN/CSA-C22.2 NO. 213-M1987
- CAN/CSA-E60079-15-02 (R2006)
- CAN/CSA-C22.2 NO. 25-1966
- CAN/CSA-C22.2 NO. 61010-1-04
- ANSI/UL Standard 913-2004
- ANSI/UL Standard 1604-1995
- UL 60079-15 2002
- UL 61010-1
Hazardous Area Approvals
-
Intrinsic Safety (iA)
- ATEX II 2 G Ex ia IIC T4 Gb, -20°C ≤ Ta ≤ 80°C (Use with current limiting, e.g.: safety barrier)
- IEC-Ex Ex ia IIC T4 Gb, -20°C ≤ Ta ≤ 80°C (Use with current limiting, e.g.: safety barrier)
- CSA Class I Division 1, Groups A, B, C, D, T4 T4: -25°C ≤ Ta ≤ 80°C (Use with current limiting, e.g.: safety barrier)
-
Non-sparking (nA)
- CSA Class I Division 2, Groups A, B, C, D
- Ex nA II T3..T4
- AEx nA II T3..T4
- T4: -25°C ≤ Ta ≤ 80°C
Ordering Information
| Model Number | Sensor Type | Measuring Range | Linearity Error |
|---|---|---|---|
| CON041 | PR6422 | 1.0mm (Standard Range) | ≤ 1.5% |
| CON041 | PR6423 | 2.0mm (Standard Range) | ≤ 1.0% |
| CON041 | PR6424 | 4.0mm (Standard Range) | ≤ 1.5% |
| CON041 | PR6426 | 8.0mm (Standard Range) | ≤ 1.5% |
| CON041/912-015 | PR6422 | 1.5mm (Extended Range) | ≤ 2.0% |
| CON041/913-030 | PR6423 | 3.0mm (Extended Range) | ≤ 1.5% |
| CON041/913-040 | PR6423 | 4.0mm (Extended Range) | ≤ 2.0% |
| CON041/914-060 | PR6424 | 6.0mm (Extended Range) | ≤ 1.0% |
| CON041/914-080 | PR6424 | 8.0mm (Extended Range) | ≤ 1.5% |
| CON041/914-100 | PR6424 | 10.0mm (Extended Range) | ≤ 2.0% |
| CON041/915-040 | PR6425 | 4.0mm (Standard Range) | ≤ 1.5% |
| CON041/915-060 | PR6425 | 6.0mm (Extended Range) | ≤ 2.0% |
| CON041/915-080 | PR6425 | 8.0mm (Extended Range) | ≤ 3.0% |
| CON041/915-100 | PR6425 | 10.0mm (Extended Range) | ≤ 4.0% |
| CON041/916-120 | PR6426 | 12.0mm (Extended Range) | ≤ 1.5% |
| CON041/916-160 | PR6426 | 16.0mm (Extended Range) | ≤ 2.0% |
| CON041/916-200 | PR6426 | 20.0mm (Extended Range) | ≤ 2.5% |
| CON041/916-240 | PR6426 | 24.0mm (Extended Range) | ≤ 3.5% |
Emerson Epro CON041 Eddy Current Signal Converter
Product Number: CON041
Category: Eddy Current Signal Converter
Function: Signal conditioning and conversion for eddy current sensors
Sensor Compatibility: PR642x series eddy current sensors
System Compatibility: MMS 3000/6000 machinery monitoring systems
Application: Converts sensor signals for vibration, position, displacement monitoring
Product Description
Sensor Signal Converter designed for critical turbo machinery applications such as steam, gas and hydro turbines, compressors, pumps and fans to measure radial and axial shaft displacement, position, eccentricity and speed/key.
| Dynamic Performance | |
| Frequency Range (-3 dB) | 0 to 20,000 Hz |
| Rise Time | <15µs |
|
NOTE: Designed for PR6422, PR6423, PR6424, PR6425, PR6426
For Extended Range Use: CON041/91x-xxx PR6425 Requires Extended Range Converter |
|
| Environmental | |
| Operating Temperature Range | -30 to 100°C (-22 to 212°F) |
| Shock and Vibration | 5g @ 60Hz @ 25°C (77°F) |
| Protection Class | IP20 |
| Power & Electrical | |
| Supply Voltage Range | -23Vto -32V (Output Range -4Vto -20V) |
| -21Vto -32V (Output Range -2Vto -18V) | |
| Physical | |
| Housing Material / Weight | PA 6.6 / ~60 grams (2.12 oz) |
| Mounting | Din Rail |
| Connections |
Screw Terminal (Max. 1.5mm2,
Wire-end Sleeves) |
Compliance and Certifications
- CE 2014/30/EU
- 2014/34/EU
- 2011/65/EU
- EN61326-1
- DIN EN 50581
- ATEX EN 60079-0:2009
- EN 60079-11:2012
- IEC-Ex IEC 60079-0:2007-10; Edition 5
- IEC 60079-11:2011; Edition: 6.0
- IEC 60079-26:2006; Edition: 2
- CSA CAN/CSA-C22.2 NO. 0-M91
- CAN/CSA-C22.2 NO. 157-92
- CAN/CSA-C22.2 NO. 213-M1987
- CAN/CSA-E60079-15-02 (R2006)
- CAN/CSA-C22.2 NO. 25-1966
- CAN/CSA-C22.2 NO. 61010-1-04
- ANSI/UL Standard 913-2004
- ANSI/UL Standard 1604-1995
- UL 60079-15 2002
- UL 61010-1
Hazardous Area Approvals
-
Intrinsic Safety (iA)
- ATEX II 2 G Ex ia IIC T4 Gb, -20°C ≤ Ta ≤ 80°C (Use with current limiting, e.g.: safety barrier)
- IEC-Ex Ex ia IIC T4 Gb, -20°C ≤ Ta ≤ 80°C (Use with current limiting, e.g.: safety barrier)
- CSA Class I Division 1, Groups A, B, C, D, T4 T4: -25°C ≤ Ta ≤ 80°C (Use with current limiting, e.g.: safety barrier)
-
Non-sparking (nA)
- CSA Class I Division 2, Groups A, B, C, D
- Ex nA II T3..T4
- AEx nA II T3..T4
- T4: -25°C ≤ Ta ≤ 80°C
Ordering Information
| Model Number | Sensor Type | Measuring Range | Linearity Error |
|---|---|---|---|
| CON041 | PR6422 | 1.0mm (Standard Range) | ≤ 1.5% |
| CON041 | PR6423 | 2.0mm (Standard Range) | ≤ 1.0% |
| CON041 | PR6424 | 4.0mm (Standard Range) | ≤ 1.5% |
| CON041 | PR6426 | 8.0mm (Standard Range) | ≤ 1.5% |
| CON041/912-015 | PR6422 | 1.5mm (Extended Range) | ≤ 2.0% |
| CON041/913-030 | PR6423 | 3.0mm (Extended Range) | ≤ 1.5% |
| CON041/913-040 | PR6423 | 4.0mm (Extended Range) | ≤ 2.0% |
| CON041/914-060 | PR6424 | 6.0mm (Extended Range) | ≤ 1.0% |
| CON041/914-080 | PR6424 | 8.0mm (Extended Range) | ≤ 1.5% |
| CON041/914-100 | PR6424 | 10.0mm (Extended Range) | ≤ 2.0% |
| CON041/915-040 | PR6425 | 4.0mm (Standard Range) | ≤ 1.5% |
| CON041/915-060 | PR6425 | 6.0mm (Extended Range) | ≤ 2.0% |
| CON041/915-080 | PR6425 | 8.0mm (Extended Range) | ≤ 3.0% |
| CON041/915-100 | PR6425 | 10.0mm (Extended Range) | ≤ 4.0% |
| CON041/916-120 | PR6426 | 12.0mm (Extended Range) | ≤ 1.5% |
| CON041/916-160 | PR6426 | 16.0mm (Extended Range) | ≤ 2.0% |
| CON041/916-200 | PR6426 | 20.0mm (Extended Range) | ≤ 2.5% |
| CON041/916-240 | PR6426 | 24.0mm (Extended Range) | ≤ 3.5% |