Motorola MVME-333S-2 Intelligent Serial Communication Controller with HMI
Motorola MVME-333S-2 Intelligent Serial Communication Controller with HMI
Motorola MVME-333S-2 Intelligent Serial Communication Controller with HMI
Popular Product

Motorola MVME-333S-2 Intelligent Serial Communication Controller with HMI


Manufacturer:Motorola

Product Number:Motorola MVME-333S-2

Payment Methods:T/T, PayPal, Western Union

Condition:New & In Stock

Warranty:1 Year

Lead Time:1-3 Working Days

Certificate:COO

Courier partners:DHL, UPS, TNT, FedEx and EMS.

Business hours:7*24

Contact Sales

Product Description

The Motorola MVME-333S-2 is a legacy industrial VMEbus intelligent serial communication controller with integrated HMI, designed to serve as a centralized hub for serial device connectivity and local operator interaction in distributed automation systems. Unlike basic serial modules (e.g., 2-port designs), Motorola MVME-333S-2 combines 6 configurable RS-232/RS-422/RS-485 channels with a rugged touchscreen and programmable function keys—eliminating the need for separate communication and HMI modules in space-constrained VME chassis.

As a key component in Motorola’s legacy VME communication lineup, Motorola MVME-333S-2 bridges the gap between host SBCs (e.g., Motorola MVME-166-11A) and field devices like sensors, actuators, and printers. Its ability to handle multi-drop RS-485 networks (up to 32 devices per port) and support industry-standard protocols like Modbus RTU makes it ideal for scaling small-to-medium automation systems. In practice, Motorola MVME-333S-2 acts as both a “communication gateway” (translating data between VMEbus and serial devices) and a “local control panel” (allowing operators to monitor statuses and adjust settings via its touchscreen)—reducing system complexity and improving operational efficiency.

Detailed Parameter Table

Parameter name Parameter value
Product model Motorola MVME-333S-2
Manufacturer Motorola (now part of Emerson Industrial Automation)
Product category Legacy Industrial VMEbus Intelligent Serial Communication Controller with HMI
Serial Channels 6 independent RS-232/RS-422/RS-485 ports (software-configurable per channel)
HMI Features 125×55mm green LCD touchscreen (120×350 resolution, 180 touch cells); 12 programmable function keys (F1–F10)
Memory Configuration 295 KB total memory; 280 KB application runtime memory; 630 KB non-volatile memory (for firmware/configuration)
Power Requirements Input voltage: 35–269 V AC (48–67 Hz); Power consumption: 12 W typical (25°C), 18 W maximum
Communication Protocols Modbus RTU, ASCII, RS-232 (DTE/DCE), RS-422 (full-duplex), RS-485 (multi-drop, up to 32 devices)
Environmental Ratings Operating temperature: -10°C–60°C (14°F–140°F); Storage temperature: -40°C–85°C (-40°F–185°F); Humidity: 5%–95% (non-condensing); Vibration: 10–2000 Hz, 1.5 g (rms)
Physical Dimensions 3U VMEbus form factor: 100mm × 160mm × 20mm (3.94in × 6.30in × 0.79in); Shipping weight: 3.8 lbs (1.72 kg)
VMEbus Compatibility A16/D16 slave interface (IEEE 1014-1987 compliant); 8 configurable interrupt vectors; Polled/DMA data transfer
Diagnostic Functions LED indicators (power, serial transmit/receive, touchscreen status, fault); Built-in self-test (BIST) for serial ports/HMI
Product Life Cycle Discontinued/Obsolete

Core Advantages and Technical Highlights

Integrated Communication + HMI Reduces Chassis Clutter: Motorola MVME-333S-2 eliminates the need for separate serial modules and HMIs by combining 6 serial channels with a rugged touchscreen in one 3U slot. For a food processing plant using Motorola MVME-147-011 as the host SBC, this means connecting 4 RS-485 temperature sensor networks and 2 RS-232 printers while using the touchscreen to display real-time batch data—saving $1,200+ in hardware costs and freeing 2 chassis slots for other components (e.g., Motorola MVME-177-003 analog input modules). The 12 programmable function keys further streamline operations, letting operators assign one-touch access to critical tasks like “start batch” or “fault reset.”

Flexible Serial Protocol Support for Legacy Devices: Motorola MVME-333S-2’s 6 channels are individually configurable for RS-232 (DTE/DCE), RS-422 (full-duplex), or RS-485 (multi-drop)—compatible with decades of industrial serial devices. A water treatment plant upgrading from legacy PLCs can use Motorola MVME-333S-2 to connect both old RS-232 pressure gauges and new RS-485 flow meters to a Motorola MVME7100-0173 SBC, avoiding costly device replacements. Its Modbus RTU/ASCII support also ensures seamless integration with SCADA systems, enabling remote monitoring of serial device data without custom software.

Rugged Design for Industrial Reliability: Motorola MVME-333S-2 is built to withstand harsh industrial conditions, with a -10°C–60°C operating range, 1.5 g vibration resistance, and a touchscreen rated for 1.5 million presses. In an automotive assembly line, this durability means Motorola MVME-333S-2 operates reliably near welding robots (electrical noise) and conveyor systems (vibration) while maintaining consistent communication with 12 RS-485-based part sensors. The non-volatile memory also preserves configuration data during power outages, ensuring fast system recovery and minimizing downtime.

Typical Application Scenarios

In a regional water utility’s pump station, Motorola MVME-333S-2 is paired with Motorola MVME-610 to monitor and control 4 remote booster pumps. It uses 4 RS-485 channels to connect to pump controllers (each reporting pressure, flow, and motor temperature) and 2 RS-232 channels to log data to a local printer and communicate with a SCADA radio. The touchscreen displays real-time pump statuses (e.g., “Pump 1: Running, 60 PSI”) and lets on-site technicians adjust setpoints (e.g., “Increase pressure to 65 PSI”) via the programmable function keys.

For a small-scale pharmaceutical packaging line, Motorola MVME-333S-2 connects 3 RS-485 barcode scanners (tracking package IDs) and 1 RS-232 label printer to a Motorola MVME-166-11A SBC. The touchscreen shows batch counts, error logs, and printer status, while operators use the function keys to trigger “print label” or “reject bad package” commands. Motorola MVME-333S-2’s Modbus RTU support also enables the SBC to send batch data to a central MES system, ensuring compliance with FDA 21 CFR Part 11 by maintaining accurate production records.

Installation Commissioning and Maintenance Instructions

Installation preparation: Before installing Motorola MVME-333S-2, verify the VME chassis has a 3U slot and the host SBC supports A16/D16 addressing. Confirm the power supply provides 35–269 V AC (48–67 Hz)–use a multimeter to check for voltage fluctuations that could damage the touchscreen. Gather tools: anti-static wristband (protects serial/HMI circuits), torque screwdriver (0.3 N·m for mounting), and a serial cable tester (to validate RS-232/RS-485 connections). For RS-485 wiring, add a 120Ω terminator at the farthest device and use shielded twisted-pair cable (24 AWG) to reduce EMI; route serial cables at least 20cm away from power cables.

Maintenance suggestions: For daily upkeep, check Motorola MVME-333S-2’s LEDs–steady power, blinking serial transmit/receive, and no fault lights indicate normal operation. Clean the touchscreen weekly with a lint-free cloth (avoid harsh chemicals) to prevent response issues. Test serial ports monthly by sending a test packet from the host SBC to each connected device; if a port fails, run the built-in BIST to isolate issues (e.g., faulty transceiver vs. cable). Replace the non-volatile memory battery annually (3V lithium) to preserve configuration data. Store spare Motorola MVME-333S-2 units in anti-static bags (15°C–25°C, 40%–60% humidity) to protect the touchscreen and serial components.

Service and Guarantee Commitment

Motorola MVME-333S-2 is backed by an 18-month warranty from Emerson for refurbished units, covering defects in serial transceivers, touchscreen components, and power circuits. If Motorola MVME-333S-2 fails (e.g., unresponsive touchscreen or serial port malfunction), Emerson provides free 7-day replacement–critical for systems where downtime disrupts production or monitoring (e.g., water utility pump stations).

For extended support, customers can purchase a 36-month service contract, including 24/7 remote troubleshooting (via phone/email), access to archived drivers (e.g., VxWorks 5.4 compatible), and on-site assistance for serial network configuration. Emerson maintains a global stock of critical components (serial transceivers, touchscreen controllers) for Motorola MVME-333S-2 until 2038, ensuring legacy systems remain operational. This commitment underscores Emerson’s dedication to supporting industrial infrastructure and helping users avoid costly full-system upgrades.

Popular Product

Motorola MVME-333S-2 Intelligent Serial Communication Controller with HMI

Manufacturer:Motorola

Product Number:Motorola MVME-333S-2

Payment Methods:T/T, PayPal, Western Union

Condition:New & In Stock

Warranty:1 Year

Lead Time:1-3 Working Days

Certificate:COO

Courier partners:DHL, UPS, TNT, FedEx and EMS.

Business hours:7*24

Contact Sales

Product Description

The Motorola MVME-333S-2 is a legacy industrial VMEbus intelligent serial communication controller with integrated HMI, designed to serve as a centralized hub for serial device connectivity and local operator interaction in distributed automation systems. Unlike basic serial modules (e.g., 2-port designs), Motorola MVME-333S-2 combines 6 configurable RS-232/RS-422/RS-485 channels with a rugged touchscreen and programmable function keys—eliminating the need for separate communication and HMI modules in space-constrained VME chassis.

As a key component in Motorola’s legacy VME communication lineup, Motorola MVME-333S-2 bridges the gap between host SBCs (e.g., Motorola MVME-166-11A) and field devices like sensors, actuators, and printers. Its ability to handle multi-drop RS-485 networks (up to 32 devices per port) and support industry-standard protocols like Modbus RTU makes it ideal for scaling small-to-medium automation systems. In practice, Motorola MVME-333S-2 acts as both a “communication gateway” (translating data between VMEbus and serial devices) and a “local control panel” (allowing operators to monitor statuses and adjust settings via its touchscreen)—reducing system complexity and improving operational efficiency.

Detailed Parameter Table

Parameter name Parameter value
Product model Motorola MVME-333S-2
Manufacturer Motorola (now part of Emerson Industrial Automation)
Product category Legacy Industrial VMEbus Intelligent Serial Communication Controller with HMI
Serial Channels 6 independent RS-232/RS-422/RS-485 ports (software-configurable per channel)
HMI Features 125×55mm green LCD touchscreen (120×350 resolution, 180 touch cells); 12 programmable function keys (F1–F10)
Memory Configuration 295 KB total memory; 280 KB application runtime memory; 630 KB non-volatile memory (for firmware/configuration)
Power Requirements Input voltage: 35–269 V AC (48–67 Hz); Power consumption: 12 W typical (25°C), 18 W maximum
Communication Protocols Modbus RTU, ASCII, RS-232 (DTE/DCE), RS-422 (full-duplex), RS-485 (multi-drop, up to 32 devices)
Environmental Ratings Operating temperature: -10°C–60°C (14°F–140°F); Storage temperature: -40°C–85°C (-40°F–185°F); Humidity: 5%–95% (non-condensing); Vibration: 10–2000 Hz, 1.5 g (rms)
Physical Dimensions 3U VMEbus form factor: 100mm × 160mm × 20mm (3.94in × 6.30in × 0.79in); Shipping weight: 3.8 lbs (1.72 kg)
VMEbus Compatibility A16/D16 slave interface (IEEE 1014-1987 compliant); 8 configurable interrupt vectors; Polled/DMA data transfer
Diagnostic Functions LED indicators (power, serial transmit/receive, touchscreen status, fault); Built-in self-test (BIST) for serial ports/HMI
Product Life Cycle Discontinued/Obsolete

Core Advantages and Technical Highlights

Integrated Communication + HMI Reduces Chassis Clutter: Motorola MVME-333S-2 eliminates the need for separate serial modules and HMIs by combining 6 serial channels with a rugged touchscreen in one 3U slot. For a food processing plant using Motorola MVME-147-011 as the host SBC, this means connecting 4 RS-485 temperature sensor networks and 2 RS-232 printers while using the touchscreen to display real-time batch data—saving $1,200+ in hardware costs and freeing 2 chassis slots for other components (e.g., Motorola MVME-177-003 analog input modules). The 12 programmable function keys further streamline operations, letting operators assign one-touch access to critical tasks like “start batch” or “fault reset.”

Flexible Serial Protocol Support for Legacy Devices: Motorola MVME-333S-2’s 6 channels are individually configurable for RS-232 (DTE/DCE), RS-422 (full-duplex), or RS-485 (multi-drop)—compatible with decades of industrial serial devices. A water treatment plant upgrading from legacy PLCs can use Motorola MVME-333S-2 to connect both old RS-232 pressure gauges and new RS-485 flow meters to a Motorola MVME7100-0173 SBC, avoiding costly device replacements. Its Modbus RTU/ASCII support also ensures seamless integration with SCADA systems, enabling remote monitoring of serial device data without custom software.

Rugged Design for Industrial Reliability: Motorola MVME-333S-2 is built to withstand harsh industrial conditions, with a -10°C–60°C operating range, 1.5 g vibration resistance, and a touchscreen rated for 1.5 million presses. In an automotive assembly line, this durability means Motorola MVME-333S-2 operates reliably near welding robots (electrical noise) and conveyor systems (vibration) while maintaining consistent communication with 12 RS-485-based part sensors. The non-volatile memory also preserves configuration data during power outages, ensuring fast system recovery and minimizing downtime.

Typical Application Scenarios

In a regional water utility’s pump station, Motorola MVME-333S-2 is paired with Motorola MVME-610 to monitor and control 4 remote booster pumps. It uses 4 RS-485 channels to connect to pump controllers (each reporting pressure, flow, and motor temperature) and 2 RS-232 channels to log data to a local printer and communicate with a SCADA radio. The touchscreen displays real-time pump statuses (e.g., “Pump 1: Running, 60 PSI”) and lets on-site technicians adjust setpoints (e.g., “Increase pressure to 65 PSI”) via the programmable function keys.

For a small-scale pharmaceutical packaging line, Motorola MVME-333S-2 connects 3 RS-485 barcode scanners (tracking package IDs) and 1 RS-232 label printer to a Motorola MVME-166-11A SBC. The touchscreen shows batch counts, error logs, and printer status, while operators use the function keys to trigger “print label” or “reject bad package” commands. Motorola MVME-333S-2’s Modbus RTU support also enables the SBC to send batch data to a central MES system, ensuring compliance with FDA 21 CFR Part 11 by maintaining accurate production records.

Installation Commissioning and Maintenance Instructions

Installation preparation: Before installing Motorola MVME-333S-2, verify the VME chassis has a 3U slot and the host SBC supports A16/D16 addressing. Confirm the power supply provides 35–269 V AC (48–67 Hz)–use a multimeter to check for voltage fluctuations that could damage the touchscreen. Gather tools: anti-static wristband (protects serial/HMI circuits), torque screwdriver (0.3 N·m for mounting), and a serial cable tester (to validate RS-232/RS-485 connections). For RS-485 wiring, add a 120Ω terminator at the farthest device and use shielded twisted-pair cable (24 AWG) to reduce EMI; route serial cables at least 20cm away from power cables.

Maintenance suggestions: For daily upkeep, check Motorola MVME-333S-2’s LEDs–steady power, blinking serial transmit/receive, and no fault lights indicate normal operation. Clean the touchscreen weekly with a lint-free cloth (avoid harsh chemicals) to prevent response issues. Test serial ports monthly by sending a test packet from the host SBC to each connected device; if a port fails, run the built-in BIST to isolate issues (e.g., faulty transceiver vs. cable). Replace the non-volatile memory battery annually (3V lithium) to preserve configuration data. Store spare Motorola MVME-333S-2 units in anti-static bags (15°C–25°C, 40%–60% humidity) to protect the touchscreen and serial components.

Service and Guarantee Commitment

Motorola MVME-333S-2 is backed by an 18-month warranty from Emerson for refurbished units, covering defects in serial transceivers, touchscreen components, and power circuits. If Motorola MVME-333S-2 fails (e.g., unresponsive touchscreen or serial port malfunction), Emerson provides free 7-day replacement–critical for systems where downtime disrupts production or monitoring (e.g., water utility pump stations).

For extended support, customers can purchase a 36-month service contract, including 24/7 remote troubleshooting (via phone/email), access to archived drivers (e.g., VxWorks 5.4 compatible), and on-site assistance for serial network configuration. Emerson maintains a global stock of critical components (serial transceivers, touchscreen controllers) for Motorola MVME-333S-2 until 2038, ensuring legacy systems remain operational. This commitment underscores Emerson’s dedication to supporting industrial infrastructure and helping users avoid costly full-system upgrades.